35
2) INSTRUCTION FOR EACH CASE OF MALFUNCTION
(1) Not working, even when operation switch is on
①
When setting temperature is done but time setting is 0
- Adjust time setting appropriately.
②
Fuse is disconnected
-
Check the fuse.
③
Circuit breaker of main meter works.
(2) Circuit breaker of main meter frequently works and temperature of wire is high
①
Lack of capacity of circuit breaker.
②
Capacity of wire is low.
- Change the breaker and wire with the rated capacity.
- Standard of breaker and wire for each model
(3) Dehydrator properly operates but dehydration result is different for each dehydration room.
①
Gap at DOOR GASKET is widened
- Check distortion of DOOR and its closure.
②
Check partition leakage at each dehydration room.
- Seal each cabinet by applying silicon.
③
Closure
of DAMPER ASS’Y of each dehydration room is different.
- Check closure of DAMPER and adjust it at certain angle during closed.
(4) Dehydrator is properly operates but dehydration is not done because of faulty moisture discharging.
①
When dehydrator is at enclosed area
- Move and locate it to the place with good ventilation.
②
When the rear of dehydration is too close with the surface of a wall
- Secure enough space between discharging outlet and a wall for good ventilation. (At least more than 30
㎝
)
(5) Main PCB, heater, ventilation motor and wiring are at normal sate but temperature is not increasing.
①
Thermo limiter works due to internal overheating
- Reset thermo limiter.
- If it works within the setting temperature, replace it, as judged to be faulty.
Model
DY-110H
DY-220H
DY-330H
Breaker
30A
30A
50A
Wire
2.5SQ
4SQ
6SQ
Adjust DAMPER of each
dehydration room to make its
closure uniform.
RESET BUTTON
Содержание DY-110H
Страница 1: ...1 MULTI PURPOSE DEHYDRATOR SERVICE MANUAL 2017 12 11...
Страница 6: ...6 2 CIRCUIT DIAGRAM DY 110H DY 220H...
Страница 7: ...7 DY 330H...
Страница 8: ...8 3 EXPLODED VIEW 1 DY 110H 2 DY 220H...
Страница 9: ...9 3 DY 330H...
Страница 10: ...10 4 CONTROL BOX ASSEMBLY DY 110H 5 CONTROL BOX ASS Y DY 220H...
Страница 11: ...11 6 CONTROL BOX ASSEMBLY DY 330H...
Страница 12: ...12 7 FAN COVER ASSEMBLY DY 110H 220H 330H 8 U COVER FRONT ASSEMBLY DY 110H...
Страница 13: ...13 9 U COVER FRONT ASSEMBLY DY 220H 10 U COVER FRONT ASSEMBLY DY 330H...
Страница 14: ...14 11 DOOR ASSEMBLY LF DY 220H 330H 12 DOOR ASSEMBLY RH DY 110H 220H 330H...
Страница 15: ...15 4 UNIT STRUCTURE 1 DY 110H...
Страница 16: ...16 2 DY 220H...
Страница 17: ...17 3 DY 330H...
Страница 38: ...38 POWER PCB...