20
(3) How to connect power
①
Turn off main source breaker and ground fault circuit interrupter on the product.
②
Open the left and right doors and unscrew the left and right screws on the bottom of unit cover locates at top of the
product.
③
Connect main wire to the terminal block of machinery by turning off ground fault circuit interrupter on the product by
opening up the unit cover. (Use the cable with the standard, matching the rated voltage of the product and power
consumption.)
④
Fix its cover again with left and right fastening screw after closing the cover.
⑤
When turning ON main source breaker and ground fault circuit interrupter, the dehydrator is on.
※
If the unit cover is not completely fixed, the product might be damaged or broken.