PLANNED MAINTENANCE
2-5
Figure 2-5: Seat Release
6.
Check the fluid level gauge on the right hand side of
the tank. See Figure 2-6.
Figure 2-6 Oil Gauge
7.
Clean the area around the hydraulic fill cap, then
open the cap (turn counterclockwise). See
Figure 2-7.
IMPORTANT
DO NOT add Hydraulic oil into the Hydraulic Breather
cap.
IMPORTANT
• It is important that the proper level of oil be
maintained at all times. Failure to check the oil
level as recommended could cause serious mast
function operating problems.
8.
Add hydraulic oil as needed.
See page 1-17
for
recommended lubricants.
9.
DO NOT OVERFILL. With the level above the FULL
line, the oil does not have enough area for expansion
when it heats up during normal operation.
10. If the fluid appears dirty or dark in color, check the
forklift’s maintenance log for the last fluid and filter
change and then change accordingly.
11. Install the fill cap, making sure it is tight.
12. Close and latch the access assembly and doors.
Содержание Bendi B40i4
Страница 2: ......
Страница 26: ...1 20 F 581 R1 INTRODUCTION SAFETY AND INSPECTION...
Страница 100: ...3 52 F 581 R1 TROUBLESHOOTING AND CORRECTIVE MAINTENANCE...
Страница 120: ...4 20 F 581 R1 CALIBRATION AND PROGRAMMING...
Страница 129: ...ENGINE WITH FUEL SYSTEM 5 9 Figure 5 10 Fuel System Troubleshooting...
Страница 133: ...ENGINE WITH FUEL SYSTEM 5 13...
Страница 134: ...5 14 F 581 R1 ENGINE WITH FUEL SYSTEM...
Страница 140: ...6 2 F 581 R1 GM ENGINE SUPPLIER PROVIDED DOCUMENTATION...