CALIBRATION AND PROGRAMMING
4-13
Figure 4-16: Defaults Screen
Defaults Screen
The “Defaults” screen shot provides featured parameters
for the Plus 1 functions. See Figure 4-16.
Below is provided a definitions list for forklift
parameters: See Figure 4-16.
1.
0,3-SETDEFPASSWORD
– Resets controller to
factory defaults, Enter ‘2008’ in the text box and
download to controller.
Figure 4-17: Tilt Screen
Tilt Screen
The “Tilt” screen shot provides featured parameters for
the Plus 1 functions. See Figure 4-17.
Below is provided a definitions list for forklift
parameters: See Figure 4-17.
1.
0,3-Tilt_RPM
– Value sets the engine RPM
commanded when the tilt lever is manipulated ~ Default
value is 1200
Figure 4-18: Engine Load Screen
Engine Load Screen
The “ENGINE LOAD” screen shot provides featured
parameters for the Plus 1 functions. See Figure 4-18.
Below is provided a definitions list for forklift
parameters: See Figure 4-18.
1.
0,3-Load_DB
– Pre defined in software, for reference
only
2.
0,3-Load_PGAIN
– Pre defined in software, for
reference only
3.
0,3-Load_IGAIN
– Pre defined in software, for
reference only
4.
0,3-Load_DGAIN
– Pre defined in software, for
reference only
5.
0,3-Load_T1
– Pre defined in software, for reference
only
6.
0,3-LOAD_RPM_X1
– Pre defined in software, for
reference only
7.
0,3-LOAD_RPM_X2
– Pre defined in software, for
reference only
8.
0,3-LOAD_RPM_X3
– Pre defined in software, for
reference only
9.
0,3-LOAD_RPM_X4
– Pre defined in software, for
reference only
10.
0,3-LOAD_RPM_X5
– Pre defined in software, for
reference only
11.
0,3-LOAD_RPM_X6
– Pre defined in software, for
reference only
12.
0,3-MAP_VALUE
– Pre defined in software, for
reference only
13.
0,3-MaxEngLoad
– Pre defined in software, for
reference only
14.
0,3-LoadPID_RampDown
– Pre defined in
software, for reference only
15.
0,3-LoadPID_RampUp
– Pre defined in software,
for reference only
16.
0,3-Propel_RPM_Pump_Y1
– Pre defined in
software, for reference only.
17.
0,3-Propel_RPM_Pump_Y2
– Pre defined in
software, for reference only.
18.
0,3-Propel_RPM_Pump_Y3
– Pre defined in
software, for reference only.
19.
0,3-Propel_RPM_Pump_Y4
– Pre defined in
software, for reference only.
20.
0,3-Propel_RPM_Pump_Y5
– Pre defined in
software, for reference only.
21.
0,3-Propel_RPM_Pump_Y6
– Pre defined in
software, for reference only.
22.
0,3-PID_On_Value
– Pre defined in software, for
reference only.
Содержание Bendi B40i4
Страница 2: ......
Страница 26: ...1 20 F 581 R1 INTRODUCTION SAFETY AND INSPECTION...
Страница 100: ...3 52 F 581 R1 TROUBLESHOOTING AND CORRECTIVE MAINTENANCE...
Страница 120: ...4 20 F 581 R1 CALIBRATION AND PROGRAMMING...
Страница 129: ...ENGINE WITH FUEL SYSTEM 5 9 Figure 5 10 Fuel System Troubleshooting...
Страница 133: ...ENGINE WITH FUEL SYSTEM 5 13...
Страница 134: ...5 14 F 581 R1 ENGINE WITH FUEL SYSTEM...
Страница 140: ...6 2 F 581 R1 GM ENGINE SUPPLIER PROVIDED DOCUMENTATION...