![lancer bridge tower Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/lancer/bridge-tower/bridge-tower_installation-manual_672755004.webp)
4
10.
Route drain line from the designated floor drain to the drip
tray and connect drain line to drain nut installed in step 6.
11. Plug in power cord to power supply then route power supply
cord to the designated grounded electrical outlet.
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME.
Make sure that all water lines
are tight and unit is dry before making any electrical
connections
!
WARNING
6.
Place gasket at the bottom of the drain then re-attach drain
fitting to drip tray, removed in Step 2.
7. Install cup rest to drip tray.
8. Route appropriate tubing from the recirculation chiller syrup
outlets to the syrup inlets on the tower. Connect tubing to
inlets using the oetiker pliers and fittings. Repeat for all syrup
connections.
9. Route appropriate tubing from the recirculation chiller water
outlets to the carbonated/plain water inlets then connect
tubing to inlet. Repeat for all water connections including the
return inlet.
A
C
E
F
G
D
B
A. Seal
B. Drip Tray
C. Mounting Plate
D. Counter
E. Upper Drain Fitting
F. Lower Drain Fitting
G. Washer
Unit is designed to be supported by a remote chiller
system or remote ice cooled system. Please see the
manufacturer’s specifications and instructions for
installation. The following are the instructions for
plumbing the remote chiller system to the tower.
NOTE
NSF listed units must be sealed to the counter.
NOTE
12. Route appropriate tubing from the syrup pump location to
the syrup inlets at the remote chiller. Repeat for all syrup
connections.
13. Route appropriate tubing from the water source to the water
inlet at the remote chiller and only connect tubing to the
water source.
14.
Turn on the water and flush the water line thoroughly.
15.
Turn off the water and connect water line to the plain water
inlet at the remote chiller.
Dispenser Setup
1. Remove the cup rest from drip tray.
2. Remove the nozzle by twisting clockwise and pulling down.
A. Nozzle
A
3. Remove the splash plate by placing both hands at the
bottom of the plate. Simultaneously lift up and pull out on the
splash plate until it ‘pops’ off of the front panel.
A. Splash Plate
A
The minimum flowing pressure to the valve must be
20 PSI (0.137 MPA). A booster pump may be required
for proper operation of the valve.
!
ATTENTION
A
B
C
A. Oetiker Pliers
B. Fitting
C. Tubing
D. Product/Water
Inlet
D