lancer bridge tower Скачать руководство пользователя страница 2

2

•  WARNING:

 Carbon Dioxide (CO

2

) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO

2

 may 

displace oxygen in the blood. 

•  WARNING: 

Prolonged exposure to CO

2

 can be harmful. Personnel exposed to high concentrations of CO

2

 gas will experience 

tremors which are followed by a loss of consciousness and suffocation. 

•  WARNING: 

If a CO

2

 gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak. 

•  WARNING: 

Strict attention must be observed in the prevention of CO

2

 gas leaks in the entire CO

2

 and soft drink system.

Carbon Dioxide (CO

2

)

Appliance is not suitable for installation where a water jet could be used. Provide an adequate potable water supply. Water pipe 

connections and fixtures directly connected to a potable water supply must be sized, installed, and maintained according to 

federal, state, and local laws. The water supply line must be at least a 3/8 inches (9.525 mm) pipe with a minimum of 20 PSI (0.137 

MPA) line pressure, but not exceeding a maximum of 50 PSI (0.345 MPA). Water pressure exceeding 50 PSI (0.345 MPA) must 

be reduced to 50 PSI (0.345 MPA) with the provided pressure regulator. Use a filter in the water line to avoid equipment damage 

and beverage off-taste. Check the water filter periodically, as required by local conditions. The water supply must be protected 

by means of an air gap, a backflow prevention device or another approved method to comply with NSF standards. A leaking inlet 

water check valve will allow carbonated water to flow back through the pump when it is shut off and contaminate the water supply. 

Ensure the backflow prevention device complies with ASSE and local standards. It is the responsibility of the installer to ensure 

compliance.

Water Notice

READ THIS MANUAL

This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this dispenser. Please 

read this guide before installation and operation of this dispenser. If service is required please call your Lancer Service Agent or Lancer 

Customer Service. Always have your model and serial number available when you call. 

 

Your Service Agent:

 

Service Agent Telephone Number: 

 

Serial Number:

 

Model Number:

SPECIFICATIONS

DIMENSIONS

 

Width:

 325 mm (12.8 inches)

 

Depth:

 439 mm (17.3 inches)

 

Height:

 610 mm (24 inches)

WEIGHT

 Shipping:

 18.1 kg (40 lbs)

 Operating:

 14.5 kg (32 lbs)

CARBON DIOXIDE (CO

2

) SUPPLY

 

Min Pressure

: 70 PSIG (0.483 MPA)

 

Max Pressure

: 80 PSIG (0.552 MPA)

FITTINGS

 

Carb Water Inlet:

 9.5 mm (3/8 inch) barb

 

Carb Water Outlet:

 9.5 mm (3/8 inch) barb

 

Plain Water Inlet:

 9.5 mm (3/8 inch) barb

 

Brand Syrup Inlets:

 9.5 mm (3/8 inch) barb

 

CO

2

 Inlet:

 9.5 mm (3/8 inch) barb

 

Drain Fitting:

 15.9 mm (5/8 inch) barb

ELECTRICAL

 

24 VDC / 2.0 Amps

FLOW RATE

 

1.5 - 2.0 ounces per second

PLAIN WATER SUPPLY

 

Min Flowing Pressure

: 20 PSIG (0.137 MPA)

 

Max Static Pressure

: 50 PSI (0.345 MPA)

This unit emits a sound pressure level below 70 dB

Appliance must be supplied by 24 VDC. Check dispenser name plate label located, underneath the head of the tower, for the 

correct electrical requirements of unit. Do not plug into a wall electrical outlet unless the current shown on the name plate label 

agrees with local current available. Follow all local electrical codes when making connections. Each dispenser must have a 

separate electrical circuit. Do not use extension cords with this unit. Do not ‘gang’ together with other electrical devices on the 

same outlet. The keyswitch does not disable the line voltage to the transformer primary. Always disconnect electrical power to the 

unit  to  prevent  personal injury before attempting any internal maintenance. The resettable breaker switch should not be used as 

a substitute for unplugging the dispenser from the power source to service the unit. Only qualified personnel should service internal 

components of electrical control housing. Make sure that all water lines are tight and units are dry before making any electrical 

connections!

Electrical Warning

Содержание bridge tower

Страница 1: ...laim with carrier Responsibility for damage to the dispenser lies with the carrier IMPORTANT SAFETY INSTRUCTIONS The installation and relocation if necessary of this product must be carried out by qualified personnel with up to date safety and hygiene knowledge and practical experience in accordance with current regulations LANCER PN 28 2852 04 Revision January 2018 The dispenser is for indoor use...

Страница 2: ... of this dispenser Please read this guide before installation and operation of this dispenser If service is required please call your Lancer Service Agent or Lancer Customer Service Always have your model and serial number available when you call Your Service Agent Service Agent Telephone Number Serial Number Model Number SPECIFICATIONS DIMENSIONS Width 325 mm 12 8 inches Depth 439 mm 17 3 inches ...

Страница 3: ... the weight of the installed unit after the cutout for the unit is made The ideal counter for installation should measure at least 25 mm 1 inch thick ATTENTION 1 Select a location that is in close proximity to a properly grounded electrical outlet within 1 5 m 5 ft of a drain and a water supply that meets the requirements shown in the Specifications section found on page 2 Min 20 mm Max 225 mm Min...

Страница 4: ...asher Unit is designed to be supported by a remote chiller system or remote ice cooled system Please see the manufacturer s specifications and instructions for installation The following are the instructions for plumbing the remote chiller system to the tower NOTE NSF listed units must be sealed to the counter NOTE 12 Route appropriate tubing from the syrup pump location to the syrup inlets at the...

Страница 5: ...connect both lines to one of the low pressure CO2 regulator manifold outlets A B C D A Line to Non Diet Syrup Pumps B Line to Diet Syrup Pumps C Line to CO2 Regulator D CO2 Regulator Manifold 9 Connect tubing routed from the diet syrup pumps to the second outlet of the low pressure CO2 regulator manifold 10 Turn on the water supply 11 Verify all Bag in Box contain syrup and check for leaks 12 Open...

Страница 6: ... not in use NOTE 21 Press the purge tab on the far left side of the screen 22 Press the Purge buttons for both the plain water and the carbonated water modules 20 From the service menu press the maintenance button 18 After you have held your finger to the upper left corner for a minimum of two 2 seconds tap all four corners of the screen in any order 19 A keypad will appear enter the designated pi...

Страница 7: ... product until it is deactivated To deactivate the purge simply press the Purge button again Up to four modules can be purged at one time Once four modules are selected all other modules are greyed out and cannot be selected NOTE Adding New Brand Flavor Module 1 In order to add a new brand or flavor module the module must first be activated 2 From the Service menu press the Configuration button 3 ...

Страница 8: ...ed flow rate in milliliters per second ml sec This number is based on the target finished drink flow rate of 44 ml sec and the desired drink ratio Finished drink flow rate 44 ml sec Ratio 5 4 1 44 ml s X 5 4 5 4 1 37 13 ml sec water flow rate 44 ml s X 1 5 4 1 6 87 ml sec syrup flow rate EXAMPLE 4 Set the Timer to the ON position and select milliliters ml as the desired unit of measurement 5 Using...

Страница 9: ... Adding New Brand Flavor Module The refrigeration unit should have been running for at least one 1 hour before attempting to set flow rates on valves The drink temperature should be no higher than 40 F 4 4 C when flow rates are set This is best done after the remote chiller has already made an ice bank NOTE A Flow Rate Ratio C Start Purge Button B Timer Icon D Unit Icon A B C D 4 Set the Timer to ...

Страница 10: ...ater level in the ratio cup If the dispensed syrup and water levels are not level remove the protective cap from the corresponding valve and use a screwdriver to adjust the brand syrup flow control A Flow Rate Ratio C Dispense Button B Timer Icon A B C A Syrup Separator in Place of Nozzle A A Syrup Separator B Ratio Cup A B Ratio Settings Table The table below shows the flow rate for the carbonate...

Страница 11: ... in the graduated cylinder If the dispensed volume does not match the value entered on the screen in step 5 remove the protective cap for the corresponding valve and use a screwdriver to adjust the carbonated water flow control 7 Repeat steps 6 and 7 if any more water flow adjustment is necessary 8 Repeat steps 2 8 for the plain water module Scheduled Maintenance As Needed Keep exterior surfaces o...

Страница 12: ...d will dispense when activated Auto signifies that the configured Sold Out Sen sor controls whether the brand can be dispensed This feature requires an optional sold out sensor kit does not come standard and is available for up to ten 10 brands at one time The following is a set of instructions on how to set up this feature If no sold out sensor is assigned then the Auto feature acts the same as t...

Страница 13: ...button if the USB drive has the brand files in the correct place NOTE To upload new flavors to the Bridge Tower User Inter face create the flavor brand file and put into a folder named flavors then repeat steps 2 5 NOTE 3 Plug the USB into the Bridge Tower port located underneath the head of the tower 2 Create a txt file in any editor software ex Notepad on Windows machines that contains the name ...

Страница 14: ...ther equipment is being cleaned follow the guidelines established by the manufacturer for that equipment NOTE Use sanitary gloves when cleaning the unit and observe all applicable safety precautions DO NOT use a water jet to clean or sanitize the unit DO NOT disconnect water lines when cleaning and sanitizing syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can dis...

Страница 15: ...solution then immerse in sanitizing solution and let sit for fifteen 15 minutes 5 Set nozzle aside and let air dry DO NOT rinse with water after sanitizing 6 Using a soft clean cloth and cleaning solution clean the nozzle injectors 7 Using a soft clean cloth sanitize the nozzle injectors and let air dry 8 Reconnect nozzle 9 Connect power 10 Taste the drink to verify that there is no off taste If o...

Страница 16: ...IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA L L C SEE HTTP WWW MPEGLA COM Third Party Software Notice This product contains third party licensed software components These licenses may be viewed in the Service Menu under Component Versions Where specific license terms entitle you to the source code of such software source code files and corre...

Отзывы: