2
• WARNING:
Carbon Dioxide (CO
2
) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO
2
may
displace oxygen in the blood.
• WARNING:
Prolonged exposure to CO
2
can be harmful. Personnel exposed to high concentrations of CO
2
gas will experience
tremors which are followed by a loss of consciousness and suffocation.
• WARNING:
If a CO
2
gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak.
• WARNING:
Strict attention must be observed in the prevention of CO
2
gas leaks in the entire CO
2
and soft drink system.
5
Carbon Dioxide (CO
2
)
Appliance is not suitable for installation where a water jet could be used. Provide an adequate potable water supply. Water pipe
connections and fixtures directly connected to a potable water supply must be sized, installed, and maintained according to
federal, state, and local laws. The water supply line must be at least a 3/8 inches (9.525 mm) pipe with a minimum of 20 PSI (0.137
MPA) line pressure, but not exceeding a maximum of 50 PSI (0.345 MPA). Water pressure exceeding 50 PSI (0.345 MPA) must
be reduced to 50 PSI (0.345 MPA) with the provided pressure regulator. Use a filter in the water line to avoid equipment damage
and beverage off-taste. Check the water filter periodically, as required by local conditions. The water supply must be protected
by means of an air gap, a backflow prevention device or another approved method to comply with NSF standards. A leaking inlet
water check valve will allow carbonated water to flow back through the pump when it is shut off and contaminate the water supply.
Ensure the backflow prevention device complies with ASSE and local standards. It is the responsibility of the installer to ensure
compliance.
!
Water Notice
READ THIS MANUAL
This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this dispenser. Please
read this guide before installation and operation of this dispenser. If service is required please call your Lancer Service Agent or Lancer
Customer Service. Always have your model and serial number available when you call.
Your Service Agent:
Service Agent Telephone Number:
Serial Number:
Model Number:
SPECIFICATIONS
DIMENSIONS
Width:
325 mm (12.8 inches)
Depth:
439 mm (17.3 inches)
Height:
610 mm (24 inches)
WEIGHT
Shipping:
18.1 kg (40 lbs)
Operating:
14.5 kg (32 lbs)
CARBON DIOXIDE (CO
2
) SUPPLY
Min Pressure
: 70 PSIG (0.483 MPA)
Max Pressure
: 80 PSIG (0.552 MPA)
FITTINGS
Carb Water Inlet:
9.5 mm (3/8 inch) barb
Carb Water Outlet:
9.5 mm (3/8 inch) barb
Plain Water Inlet:
9.5 mm (3/8 inch) barb
Brand Syrup Inlets:
9.5 mm (3/8 inch) barb
CO
2
Inlet:
9.5 mm (3/8 inch) barb
Drain Fitting:
15.9 mm (5/8 inch) barb
ELECTRICAL
24 VDC / 2.0 Amps
FLOW RATE
1.5 - 2.0 ounces per second
PLAIN WATER SUPPLY
Min Flowing Pressure
: 20 PSIG (0.137 MPA)
Max Static Pressure
: 50 PSI (0.345 MPA)
This unit emits a sound pressure level below 70 dB
Appliance must be supplied by 24 VDC. Check dispenser name plate label located, underneath the head of the tower, for the
correct electrical requirements of unit. Do not plug into a wall electrical outlet unless the current shown on the name plate label
agrees with local current available. Follow all local electrical codes when making connections. Each dispenser must have a
separate electrical circuit. Do not use extension cords with this unit. Do not ‘gang’ together with other electrical devices on the
same outlet. The keyswitch does not disable the line voltage to the transformer primary. Always disconnect electrical power to the
unit to prevent personal injury before attempting any internal maintenance. The resettable breaker switch should not be used as
a substitute for unplugging the dispenser from the power source to service the unit. Only qualified personnel should service internal
components of electrical control housing. Make sure that all water lines are tight and units are dry before making any electrical
connections!
F
Electrical Warning