background image

Bridge Tower

LANCER INSTALLATION GUIDE

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for 

immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access Contact Lancer Customer Service for assistance as required.

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit, 

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

IMPORTANT SAFETY INSTRUCTIONS

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

LANCER PN: 28-2852/04

Revision: January 2018

The dispenser is for indoor use only. This appliance is to be installed in a location where its use can be overseen by trained 

personnel. This unit is not a toy. Children should be supervised not to play with appliance. It should not be used by children or 

infirm persons without supervision. This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance shall not be performed by 

children without supervision. The min/max ambient operating temperature for the dispenser is 4°C to 32°C (40°F to 90°F). Do not 

operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of the unit and contact 

authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained personnel. Applicable safety 

precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

®

320

Содержание bridge tower

Страница 1: ...laim with carrier Responsibility for damage to the dispenser lies with the carrier IMPORTANT SAFETY INSTRUCTIONS The installation and relocation if necessary of this product must be carried out by qualified personnel with up to date safety and hygiene knowledge and practical experience in accordance with current regulations LANCER PN 28 2852 04 Revision January 2018 The dispenser is for indoor use...

Страница 2: ... of this dispenser Please read this guide before installation and operation of this dispenser If service is required please call your Lancer Service Agent or Lancer Customer Service Always have your model and serial number available when you call Your Service Agent Service Agent Telephone Number Serial Number Model Number SPECIFICATIONS DIMENSIONS Width 325 mm 12 8 inches Depth 439 mm 17 3 inches ...

Страница 3: ... the weight of the installed unit after the cutout for the unit is made The ideal counter for installation should measure at least 25 mm 1 inch thick ATTENTION 1 Select a location that is in close proximity to a properly grounded electrical outlet within 1 5 m 5 ft of a drain and a water supply that meets the requirements shown in the Specifications section found on page 2 Min 20 mm Max 225 mm Min...

Страница 4: ...asher Unit is designed to be supported by a remote chiller system or remote ice cooled system Please see the manufacturer s specifications and instructions for installation The following are the instructions for plumbing the remote chiller system to the tower NOTE NSF listed units must be sealed to the counter NOTE 12 Route appropriate tubing from the syrup pump location to the syrup inlets at the...

Страница 5: ...connect both lines to one of the low pressure CO2 regulator manifold outlets A B C D A Line to Non Diet Syrup Pumps B Line to Diet Syrup Pumps C Line to CO2 Regulator D CO2 Regulator Manifold 9 Connect tubing routed from the diet syrup pumps to the second outlet of the low pressure CO2 regulator manifold 10 Turn on the water supply 11 Verify all Bag in Box contain syrup and check for leaks 12 Open...

Страница 6: ... not in use NOTE 21 Press the purge tab on the far left side of the screen 22 Press the Purge buttons for both the plain water and the carbonated water modules 20 From the service menu press the maintenance button 18 After you have held your finger to the upper left corner for a minimum of two 2 seconds tap all four corners of the screen in any order 19 A keypad will appear enter the designated pi...

Страница 7: ... product until it is deactivated To deactivate the purge simply press the Purge button again Up to four modules can be purged at one time Once four modules are selected all other modules are greyed out and cannot be selected NOTE Adding New Brand Flavor Module 1 In order to add a new brand or flavor module the module must first be activated 2 From the Service menu press the Configuration button 3 ...

Страница 8: ...ed flow rate in milliliters per second ml sec This number is based on the target finished drink flow rate of 44 ml sec and the desired drink ratio Finished drink flow rate 44 ml sec Ratio 5 4 1 44 ml s X 5 4 5 4 1 37 13 ml sec water flow rate 44 ml s X 1 5 4 1 6 87 ml sec syrup flow rate EXAMPLE 4 Set the Timer to the ON position and select milliliters ml as the desired unit of measurement 5 Using...

Страница 9: ... Adding New Brand Flavor Module The refrigeration unit should have been running for at least one 1 hour before attempting to set flow rates on valves The drink temperature should be no higher than 40 F 4 4 C when flow rates are set This is best done after the remote chiller has already made an ice bank NOTE A Flow Rate Ratio C Start Purge Button B Timer Icon D Unit Icon A B C D 4 Set the Timer to ...

Страница 10: ...ater level in the ratio cup If the dispensed syrup and water levels are not level remove the protective cap from the corresponding valve and use a screwdriver to adjust the brand syrup flow control A Flow Rate Ratio C Dispense Button B Timer Icon A B C A Syrup Separator in Place of Nozzle A A Syrup Separator B Ratio Cup A B Ratio Settings Table The table below shows the flow rate for the carbonate...

Страница 11: ... in the graduated cylinder If the dispensed volume does not match the value entered on the screen in step 5 remove the protective cap for the corresponding valve and use a screwdriver to adjust the carbonated water flow control 7 Repeat steps 6 and 7 if any more water flow adjustment is necessary 8 Repeat steps 2 8 for the plain water module Scheduled Maintenance As Needed Keep exterior surfaces o...

Страница 12: ...d will dispense when activated Auto signifies that the configured Sold Out Sen sor controls whether the brand can be dispensed This feature requires an optional sold out sensor kit does not come standard and is available for up to ten 10 brands at one time The following is a set of instructions on how to set up this feature If no sold out sensor is assigned then the Auto feature acts the same as t...

Страница 13: ...button if the USB drive has the brand files in the correct place NOTE To upload new flavors to the Bridge Tower User Inter face create the flavor brand file and put into a folder named flavors then repeat steps 2 5 NOTE 3 Plug the USB into the Bridge Tower port located underneath the head of the tower 2 Create a txt file in any editor software ex Notepad on Windows machines that contains the name ...

Страница 14: ...ther equipment is being cleaned follow the guidelines established by the manufacturer for that equipment NOTE Use sanitary gloves when cleaning the unit and observe all applicable safety precautions DO NOT use a water jet to clean or sanitize the unit DO NOT disconnect water lines when cleaning and sanitizing syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can dis...

Страница 15: ...solution then immerse in sanitizing solution and let sit for fifteen 15 minutes 5 Set nozzle aside and let air dry DO NOT rinse with water after sanitizing 6 Using a soft clean cloth and cleaning solution clean the nozzle injectors 7 Using a soft clean cloth sanitize the nozzle injectors and let air dry 8 Reconnect nozzle 9 Connect power 10 Taste the drink to verify that there is no off taste If o...

Страница 16: ...IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA L L C SEE HTTP WWW MPEGLA COM Third Party Software Notice This product contains third party licensed software components These licenses may be viewed in the Service Menu under Component Versions Where specific license terms entitle you to the source code of such software source code files and corre...

Отзывы: