Lake Shore Model 475 Gaussmeter User’s Manual
Operation
4-31
The next screen appears as a prompt for returning the instrument parameters to default values. Default parameter values
are listed in Table 4-1.
Se l e c t Wi t h ° ®
De f a u l t Va l u e s No
Use the
s
or
t
keys to select Yes for default values and No to continue without changing the parameter values. Press
Enter
to accept the new selection and return to the normal display. Press
Escape
to cancel the new selection and return
to the normal display.
Table 4-1. Default Parameter Values
Alarm and Relay
Alarm ....................................................... Off
Alarm Mode ................................ Magnitude
Alarm Trigger ................................... Outside
Alarm Sort ............................................... Off
Alarm Audible .......................................... On
Relay 1 ........................................ Manual Off
Relay 2 ........................................ Manual Off
Analog Output
Analog Output 3 Mode ............................ Off
Analog Output 3 Polarity ................... Bipolar
Analog Output 3 Limit ........................... 10V
Analog Output 3 Manual Out ................... 0 *
Computer Interface
Baud ...................................................... 9600
IEEE Address ............................................ 12
IEEE Terminators ............................... CR/LF
Trigger Output ......................................... Off
Datalog Rate ....................................... 1 rdg/s
Display
Bottom Line ................................. Temp/Freq
Brightness .............................................. 75%
Field Units ........................................... Gauss
Temperature Units .................................... °C
Field Control
Control Mode ....................................... Off *
Setpoint ................................................. 0 G *
Setpoint Ramp Rate .....................3.5 kG/min
Control Slope Limit ........................10 V/min
Proportional (P) .......................................... 10
Integral (I) .............................................. 1 sec
Filter
DC Resolution ............................................... 5
RMS Filter Band .................................... Wide
RMS Wide Band Filter .......................... None
RMS Narrow Band Filter ...................... 60 Hz
RMS Lowpass Filter ........................... 140 Hz
Keypad Locking
Mode ............................................... Unlocked
Lock Code ................................................. 123
Measurement
Measurement Mode .................................. DC
Autorange .................................................. On
Field Compensation ................................... On
Temperature Compensation ....................... On
Peak Mode ............................................. Pulse
Peak Display ........................................... Both
Max Hold .................................................. Off
Max Mode ..................................... Magnitude
Max Display ........................................... Both
Relative ..................................................... Off
Remote/Local
Remote/Local ...................................... Local *
* Indicates value is also initialized on power up.
Содержание 475
Страница 16: ...Lake Shore Model 475 Gaussmeter User s Manual 1 6 Introduction 1 4 SAFETY SYMBOLS ...
Страница 25: ...Lake Shore Model 475 Gaussmeter User s Manual Background 2 9 Figure 2 8 Examples of PI Control ...
Страница 36: ...Lake Shore Model 475 Gaussmeter User s Manual 3 10 Installation This Page Intentionally Left Blank ...
Страница 68: ...Lake Shore Model 475 Gaussmeter User s Manual 4 32 Operation This Page Intentionally Left Blank ...
Страница 82: ...Lake Shore Model 475 Gaussmeter User s Manual 6 6 Remote Operation Figure 6 2 Model 475 Status System ...