Lake Shore Model 475 Gaussmeter User’s Manual
4-12
RMS Operation
Operation
4.7
RMS MEASUREMENT MODE
To measure periodic, AC fields, press the
RMS
key on the front panel. In RMS measurement mode, the keypad and
functionality of the Model 475 is optimized to provide the best interaction for RMS measurements. The keypad features
are described in paragraphs 4.7.1 through 4.7.8.
Due to the flexibility of the filtering capability of the Model 475, the instrument communicates the present filter setting
when entering RMS measurement mode. When the RMS key is pressed, the following message will appear for
approximately 3 seconds. Note: this display screen is an example of having the 100 Hz bandpass filter selected (refer to
Paragraph 4.7.2 for filter configuration).
Fi l t Cent er 100 Hz
4.7.1
RMS Operation Select Range and Autorange
The Model 475 reads each Lake Shore probe type: High Stability, High Sensitivity, and Ultra-High Sensitivity. The
tables below list full scale ranges for each probe sensitivity, along with the display resolution. Measurement resolution
(noise floor) varies depending on probe and application, but the Model 475 can typically measure signals as small as
0.1% of full scale range.
High Stability Probe (HST)
Gauss
Tesla
Oersted
Amp/meter
Range and Resolution
Range and Resolution
Range and Resolution
Range and Resolution
±350.00 kG
±35.000 T
±350.00 kOe
±28.000 MA/m
±35.000 kG
±3.5000 T
±35.000 kOe
±2.8000 MA/m
±3.5000 kG
±350.00 mT
±3.5000 kOe
±280.00 kA/m
±350.00 G
±35.000 mT
±350.00 Oe
±28.000 kA/m
±35.000 G
±3.5000 mT
±35.000 Oe
±2.8000 kA/m
High Sensitivity Probe (HSE)
Gauss
Tesla
Oersted
Amp/meter
Range and Resolution
Range and Resolution
Range and Resolution
Range and Resolution
±35.000 kG
±3.5000 T
±35.000 kOe
±2.8000 MA/m
±3.5000 kG
±350.00 mT
±3.5000 kOe
±280.00 kA/m
±350.00 G
±35.000 mT
±350.00 Oe
±28.000 kA/m
±35.000 G
±3.5000 mT
±35.000 Oe
±2.8000 kA/m
±3.5000 G
±350.00 µT
±3.5000 Oe
±280.00 A/m
Ultra-High Sensitivity Probe (UHS)
Gauss
Tesla
Oersted
Amp/meter
Range and Resolution
Range and Resolution
Range and Resolution
Range and Resolution
±35.000 G
±3.5000 mT
±35.000 Oe
±2.8000 kA/m
±3.5000 G
±350.00 µT
±3.5000 Oe
±280.00 A/m
±350.00 mG
±35.000 µT
±350.00 mOe
±28.000 A/m
±35.000 mG
±3.5000 µT
±35.000 mOe
±2.8000 A/m
Содержание 475
Страница 16: ...Lake Shore Model 475 Gaussmeter User s Manual 1 6 Introduction 1 4 SAFETY SYMBOLS ...
Страница 25: ...Lake Shore Model 475 Gaussmeter User s Manual Background 2 9 Figure 2 8 Examples of PI Control ...
Страница 36: ...Lake Shore Model 475 Gaussmeter User s Manual 3 10 Installation This Page Intentionally Left Blank ...
Страница 68: ...Lake Shore Model 475 Gaussmeter User s Manual 4 32 Operation This Page Intentionally Left Blank ...
Страница 82: ...Lake Shore Model 475 Gaussmeter User s Manual 6 6 Remote Operation Figure 6 2 Model 475 Status System ...