2L6/2N6/2N5/2N4
1-4-25
6500
DF eject paper sensor
non arrival jam
DF eject paper sensor (DFMTS) does not turn on
within specified time of DF middle eject sensor
(DFMES) turning on.
K
6510
DF eject paper sensor
stay jam
DF eject paper sensor (DFMTS) is not turned off since
the bundle discharge starts (4000-sheet finisher).
K
6511
DF eject paper sensor (DFMTS) is not turned off since
the bundle discharge starts (1000-sheet finisher).
K
6600
DF drum sensor non
arrival jam
DF drum sensor (DFDRS) does not turn on within
specified time of DF paper entry sensor (DFPES) turn-
ing on.
K
6610
DF drum sensor stay jam DF drum sensor (DFDRS) is not turned off within spec-
ified time of its turning on.
K
6710
Center folding unit stay
jam
During paper conveying to center folding unit, DF drum
sensor (DFDRS) is not turned off within specified time
of its turning on.
K
6810
DF side registration sen-
sor 1 stay jam
DF side registration sensor 1 (DFSRS1) is not turned
off within specified time after driving the DF side regis-
tration motor 1 (DFSRM1) (4000-sheet finisher).
K
6811
DF side registration sensor 1 (DFSRS1) is not turned
off within specified time after driving the DF side regis-
tration motor 1 (DFSRM1) (1000-sheet finisher).
K
6910
DF side registration sen-
sor 2 stay jam
DF side registration sensor 2 (DFSRS2) is not turned
off within specified time after driving the DF side regis-
tration motor 2 (DFSRM2) (4000-sheet finisher).
K
6911
DF side registration sensor 2 (DFSRS2) is not turned
off within specified time after driving the DF side regis-
tration motor 2 (DFSRM2) (1000-sheet finisher).
K
7000
DF staple operation error DF staple sensor (DFSTS) is not turned on within
specified time after driving the DF staple motor
(DFSTM) (4000-sheet finisher).
K
7001
DF staple sensor (DFSTS) is not turned on within
specified time after driving the DF staple motor
(DFSTM) (1000-sheet finisher).
K
7100
CF paper entry sensor
non arrival jam
CF paper entry sensor (CFPES) is not turned on even
if a specified time has elapsed after the machine eject
signal was received.
M
7110
CF paper entry sensor
stay jam
CF paper entry sensor (CFPES) is not turned off within
specified time of its turning on.
M
7200
CF eject sensor non
arrival jam
CF eject sensor (CFES) is not turned on within speci-
fied time since centerfold operation starts.
M
7210
CF eject sensor stay jam During centerfold operation, CF eject sensor (CFES) is
not turned off within specified time of its turning on.
M
Code
Contents
Conditions
Jam
location*
*: Refer to figure 1-4-1 for paper misfeed indication (see page 1-4-1).
Содержание TASKalfa 3051ci
Страница 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Страница 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Страница 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Страница 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Страница 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Страница 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...