![Kyocera TASKalfa 3051ci Скачать руководство пользователя страница 179](http://html.mh-extra.com/html/kyocera/taskalfa-3051ci/taskalfa-3051ci_service-manual_2015918179.webp)
2L6/2N6/2N5/2N4
1-4-178
8210
DF slide motor error
When initial operation, DF sta-
ple sensor does not turn on
within 3 s.
DF slide motor
1. Execute U240 Motor - Staple Move to
check the finisher operation (see page
1-3-134).
2. Manipulate the staple unit back and forth
to check it is smoothly operable.
3. Check that the drive from the motor
reaches the staple unit.
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF slide motor and DF main PWB
(YC12) (4000-sheet finisher)
DF slide motor and DF main PWB
(YC10) (1000-sheet finisher)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the DF slide motor.
DF staple sensor
1. Execute U241 Finisher - Width Staple
HP to check the finisher switch (see
page 1-3-136).
2. Check that the sensor and its mounting
bracket are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF staple sensor and DF main PWB
(YC22) (4000-sheet finisher)
DF staple sensor and DF main PWB
(YC20) (1000-sheet finisher)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the DF staple sensor.
DF main PWB
Replace the DF main PWB (Refer to the
service manual for the document finisher).
Code
Contents
Related parts
Check procedures/
corrective measures
Содержание TASKalfa 3051ci
Страница 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Страница 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Страница 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Страница 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Страница 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Страница 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...