2L6/2N6/2N5/2N4
1-4-105
3210
CIS lamp error
When input value at the time
of CIS illumination does not
exceed the threshold value
between 5 s.
CIS
1. Execute U906 Separating Operation
Release (see page 1-3-224).
2. Execute CCD of U061 lamp check (see
page 1-3-55).
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
CIS and DPSHD PWB (YC2)
DPSHD PWB (YC3) and DP relay PWB
(YC2)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the CIS and execute U091 and
U411 (see page 1-3-71,1-3-173).
DPSHD PWB
Replace the DPSHD PWB.
DP relay PWB
Replace the DP relay PWB.
3220
CCD lamp activation error
The threshold is calculated for
colors at initialization and the
pixel which does not exceed
that value is greater than
1000.
CIS
1. Execute U906 Separating Operation
Release (see page 1-3-224).
2. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
LED lamp PWB and ISC PWB (YC6)
CCD PWB (YC2) and ISC PWB (YC9)
ISC PWB (YC3) and Main PWB (YC11)
3. If the wiring is disconnected, shorted or
grounded, replace the wiring.
LED PWB and execut U411 (see page
1-3-173).
ISC PWB
Replace the ISC PWB and execute U411
(see page 1-3-173).
Main PWB
Replace the main PWB (see page 1-5-72).
Code
Contents
Related parts
Check procedures/
corrective measures
Содержание TASKalfa 3051ci
Страница 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Страница 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Страница 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Страница 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Страница 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Страница 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...