2L6/2N6/2N5/2N4-4
1-4-199
(3) System Error (Fxxxx) Outline
The document is subscribed to describe the outline of the factors of the Fxxx errors that are not described in
the
service manual. Please utilize it to refer to checking the factors.
Please utilize it as the measures when the system is not recovered after power off/on
or it frequently occurs.
It may be from the hardware factor while the error (Fxxx) is indicated.
Please initially check the following.
Check the DDR2 memory and neighboring parts:
Check the contact of YS1 or YS2 with the memory. Replace the memory if the error repeats.
Check the HDD if the error repeats after replacing the main board.
Take care, however, of handling the data when formatting or replacing the HDD.
Check the HDD : Replace the HDD if the error repeats after formatting the HDD.