2L6/2N6/2N5/2N4
1-4-57
(11) Electrical parts that could cause paper jam at the DF paper entry,feedshift and
subtray left eject part
Timing of detection
Corrective Action
Jam code
J610x,J611x,J620x,J621x,J630x,J631x
Related parts
DF paper entry motor (DFPEM)
DF feedshift solenoid 3 (DFFSSOL)
DF middle motor (DFMM)
DP main PWB (DFMPWB)
DF eject motor (DFEM)
BR conveying motor 1 (BRCM1)
BR conveying motor 2 (BRCM2)
DF paper entry sensor (DFPES)
DF middle sensor (DFMES)
DF sub eject sensor (DFSES)
Checking
procedure at the
occurrence of
J61XX
Corrective action at the occurrence of
J61XX
On/Off control signal output connector
(terminal), point of checking connection
1
Items for Initial Checks
see page 1-4-29
2
DF paper entry sensor (DFPES) :
Conduct connectivity check, mounting
location check, operation check
(U241:Finisher HP)
DF main PWB YC21-9
3
DF feedshift solenoid 3 (DFFSSOL):
Check to see the feedshift guide 3 is
switchable (U240: Solenoied - Subtray)
DF main PWB YC18-12,13
4
DF paper entry motor (DFPEM) :
Operation check (U240: Motor Feed
In(H),Feed In(L))
DF main PWB YC12-13 to 16
5
BR conveying motor 1 (BRCM1) , BR
conveying motor 2 (BRCM2) : Operation
check (U030: Bridge1 , Bridge2)
6
DF main PWB(DFMPWB) : Replace
Содержание TASKalfa 3051ci
Страница 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Страница 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Страница 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Страница 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Страница 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Страница 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...