Kyland Technology (Shanghai) Co., Ltd PTS-DR200 Time Server
- 27 -
Items
Parameters
Description
Delay
Measurement
Interval
-8~4
STOP
Set PTP Clock sending delay measurement message rate of
Slave mode.
-8~4: Set a number for interval. If it is n, the actual interval is
2
n
seconds.
STOP: Don’t send delay measurement message.
Default value is STOP.
When PTP mode is Slave or Boundary, if this parameter is
STOP , it means PTP cannot send Delay, PDelay message
according to Delay Measurement Mode.
Domain1
0~3
Set the working domain name for PTP message of ETH0.
Range is between 0 and 3.
Default value is 0.
Domain2
0~3
Set the working domain name for PTP message of ETH1.
Range is between 0 and 3.
Default value is 0.
Priority1
0~255
Set working priority for PTP message of ETH0.
Range is between 0 and 255.
Default value is 0.
Priority2
0~255
Set working priority for PTP message of ETH1.
Range is between 0 and 255.
Default value is 0.
PTP Media
802.3
IPv4
Set the transmission protocol for PTP.
802.3: PTP uses IEEE802.3 transmission protocol.
IPv4: PTP uses Ipv4 transmission protocol.
Rx
Compensation
0ns
Set the time delay compensation for receiving PTP message.
Unit is nanosecond(ns);
Range is between -999999999ns and 999999999ns.
Default value is 0ns.
Tx
Compensation
0ns
Set the time delay compensation for sending PTP message.
Unit is nanosecond(ns);
Range is between -999999999ns and 999999999ns.
Default value is 0ns.
vLan
Enable
YES
NO
Set whether or not have vLan information in PTP message.
YES: Set PTP message with vLan message.
NO: Set PTP message without vLan message.
vLan
0~7
Set vLan priority of PTP message.