background image

Kyland Technology (Shanghai) Co., Ltd               PTS-DR200 Time Server 

- 25 - 

Items 

Parameters 

Description 

Set stop time to define what time to start DST. 
Format is 24 hours format. 
Range is between 00:00 and 24:00. 
Default value is 00:00. 

  The Daylight Saving Time (DST) will define by what month, 

week, day and time to stop. 

Press ‘Save’ button to save the current setting when you change setting. 

 

3.5.3. NTP Settings 

Press ‘NTP’ on the left navigation bar to show NTP setting screen.   
The NTP setting screen will be shown as: 

 

[Figure 3-16] NTP Setting Screen 

Table 15 – NTP Setting 

Items

 

Parameters

 

Description

 

NTP Server

 

Enable 

Disable 

Activate NTP server feature. 
Enable: Make NTP server start working; 
Disable: Make NTP server stop working.

 

NTP UTC Offset 

0.00H

 

Set time offset between NTP time stamp and UTC. If NTP time 
stamp needs time offset, please set this parameter. 
Unit is Hour(H); 
Range is between -12H and 12H. 
Default value is 0.00H. 

Press ‘Save’ button to save the current setting when you change setting.

 

 

3.5.4. PTP Settings (Optional) 

Press ‘PTP’ on the left navigation bar to show PTP setting screen.   
The PTP setting screen will be shown as: 

Содержание PTS-DR200

Страница 1: ...PTS DR200 Time Server Operation Manual Kyland Technology Shanghai Co Ltd Version Copyright R7 ...

Страница 2: ...Kyland Technology Shanghai Co Ltd Room 802 Building 5 No 3000 Longdong Avenue Pudong District Shanghai China Tel 86 21 80321288 Fax 86 21 80321289 ...

Страница 3: ... Information 11 3 4 2 Source Status 12 3 4 3 Clock Status 14 3 5 Configuration 15 3 5 1 Sync Source Settings 16 3 5 2 Clock Settings 21 3 5 3 NTP Settings 25 3 5 4 PTP Settings Optional 25 3 5 5 Output Settings 28 3 5 6 Network Settings 36 3 5 7 TMS Settings Optional 37 3 6 System 45 3 6 1 Gateway 46 3 6 2 Route 46 3 6 3 Configuration 47 3 6 4 Firmware 47 3 6 5 SNMP Optional 48 3 7 Management 48 3...

Страница 4: ...id any exposed metal wires because they may be oxidized or electrified Install the device in accordance with related national and local regulations Before power on make sure the power supply is within the allowed range of the device High voltage may damage the device Power connectors and other connectors should be firmly interconnected Do not plug in or out the power supply with wet hands When the...

Страница 5: ...normally changed The equipment emits odor smoke or abnormal noise Indicator Flag Note Highlight the important information and use of skills necessary to the operation of your tips supplement and instructions Attention Remind you of operation must be pay attention to and follow such as not operating in accordance with the requirements equipment damage may arise or other unpredictable result Alarm W...

Страница 6: ...iple time source input PTS DR200 has multi time source selection logical and Sky Grounding time backup function inside It also supports IEEE1588 PTP Precision Timing Protocol NTP Network Time Protocol IRIG B 1PPS 1PPM 1PPH and TOD etc time synchronization signal output as time synchronization purpose PTS DR200 supports TMS Time Management System features to report PTS DR200 time status by IEC61850...

Страница 7: ... Alarm Status Indicator Light 2 LOCK Time Lock Status Indicator Light 3 FIX Satellite Position Fix Status Indicator Light 4 ANT Antenna Status Indicator Light 5 LCD with backlight 6 B L B L Button show message and turn on backlight 7 AC 1 2 Two Terminal output ports IRIG B modulated signal 8 P 1 4 Four Terminal TTL output ports PPS PPM PPH IRIG B configurable 9 BNC Two BNC TTL output ports PPS PPM...

Страница 8: ... IRIG B configurable SO TxD is TOD serial message 11 ETH0 ETH0 Copper and Optical multiplex Ethernet interface NTP PTP signal 12 ETH1 ETH1 Copper and Optical multiplex Ethernet interface NTP PTP signal 13 FO Optical Fiber output port PPS PPM PPH IRIG B configurable 14 FI Optical Fiber input port IRIG B unmodulated signal 1 2 3 4 5 6 7 Figure 2 2 PTS DR200 Top Panel Table 2 Top Panel of PTS DR200 N...

Страница 9: ...rminal output port with NO and NC 7 PWR Power Supply Terminal Input Interface Power Grounding PGND DC or AC L DC or AC N Please confirm power supply parameters before use 2 2 Output PTS DR200 supports one serial output channel named SO and five output channels named O1 O2 O3 O4 O5 Each interface can bind one fixed output channel and one configurable output signal The output definition will be show...

Страница 10: ...ton can switch different screens to show different messages 17 07 01 06 02 36 Figure 2 3 PTS DR200 Local Date Time Information GPS LOCK 11 OK 3D TI LOCK D 0 100 FI LOCK D 0 100 PTP LOCK S P2P Figure 2 4 PTS DR200 Time Source Information HV R0914 Figure 2 5 PTS DR200 Hardware Version Information SV R7 51 Figure 2 6 PTS DR200 Software Version Information OS 0703 17 12 33 Figure 2 7 PTS DR200 System ...

Страница 11: ...LARM System Alarm On Device is abnormal Off Device is normal LOCK Time Lock Flash 1 second Clock is LOCK status Flash 3 seconds Clock is HOLD status Off Clock is initializing FIX Satellite Position Fix On Position fix is 3D type Off Position fix is invalid ANT Antenna Status On Antenna is normal Off Antenna is abnormal The enclosure is one part of the whole cooling system Don t cover it when it wo...

Страница 12: ...ult user name is admin the default password also is admin PTS DR200 time server supports user to modify the password of admin after you login WEB management system Before you access WEB management system of PTS DR200 time server please confirm you might access this Ethernet port if find any problems you should check the network whether or not is ready maybe connection cable has some broken or some...

Страница 13: ... DR200 time server supports English and Chinese System can switch language to Chinese language by 中文 option on login screen and default screen 3 4 Status The WEB management system supports to view time status by WEB The status information can help user to easy know the current status and help them to analyze problems as soon as possible Press Status to go to the status screen on the top of navigat...

Страница 14: ...Parameters Description Source Status Normal Alarm Show the time source status Normal The time source can use Alarm The time source cannot use Satellite Number 0 128 Show how many satellites work together Range is between 0 and 128 Default value is 0 Antenna Status Normal Alarm Show the antenna status Normal The antenna can use Alarm The antenna cannot use Source Bump Status Normal Alarm Show the t...

Страница 15: ... bump status Normal The time source has not bump data Alarm The time source has bump data Source Priority 1 10 Show the priority for time source 1 is highest source and 10 is lowest source It has 10 levels System can select best time sources by source priority Select IRIG B2 in Source Channel the screen will be shown as Figure 3 7 Source Status Screen IRIG B2 Table 7 Source Status Information IRIG...

Страница 16: ...n PTP Table 8 Source Status Information PTP Items Parameters Description Source Status Normal Alarm Show the time source status Normal The time source can use Alarm The time source cannot use Source Bump Status Normal Alarm Show the time source bump status Normal The time source has not bump data Alarm The time source has bump data Source Priority 1 10 Show the priority for time source 1 is highes...

Страница 17: ...e oscillator is locked Initial Status Initializing Initialized Show the initial status Initializing The device is initializing Initialized The device is initialized Hold Status Tracking Hold Show the hold status Tracking The device is tracking with time source Hold The device lost time source Longitude 0 00 Show longitude of geographic position information Latitude 0 00 Show latitude of geographic...

Страница 18: ...ft navigation bar to show synchronization source setting screen Press Source Channel to select SAT1 IRIG B1 IRIG B2 PTP channel SAT1 source signal comes from ANT interface IRIG B1 source signal default comes from FI and also can be set to TI by manual IRIG B2 source signal default comes from TI and also can be set to FI by manual PTP source signal comes from ETH0 or ETH1 interface If select SAT1 i...

Страница 19: ... module for each satellite channel you might use this parameter to make it work at right mode Different satellite receiver module has different definition on these options Before you use this device please contact technical support to confirm how to use them UBLOX8 will define as following description Auto Make satellite automatic working at GPS mode A BDS Make satellite priority working at BDS mo...

Страница 20: ...rameter can make satellite working at GPS mode by mixed position fix mode with GPS and BDS Antenna Compensation 0ns According to different antenna types and lengths system can set time delay compensation for satellite channel Unit is nanosecond ns Range is between 999999999ns and 999999999ns Default value is 0ns Source Priority 1 10 Set the priority for time source 1 is highest source and 10 is lo...

Страница 21: ...e NONE Make it doesn t work Input Channel FI TI Set IRIG B input time signal coming from which hardware channel There are two channel one is FI interface and another is TI interface please refer to section Panel and find where these interfaces are Time Format DC DC To set IRIG B input signal format DC positive polarity DC high level is 1 DC negative polarity DC low level is 1 UTC Offset 0 00H Set ...

Страница 22: ...ake it work at redundancy time source NONE Make it doesn t work Input Channel FI TI Set IRIG B input time signal coming from which hardware channel There are two channel one is FI interface and another is TI interface please refer to section Panel and find where these interfaces are Time Format DC DC To set IRIG B input signal format DC positive polarity DC high level is 1 DC negative polarity DC ...

Страница 23: ...s 10 levels System can select best time sources by source priority Source Mode SYNC PEER NONE Set source working mode SYNC Make it work at individual time source PEER Make it work at redundancy time source NONE Make it doesn t work Working Mode Single Set time source working logic Single The system can work at one valid time source Press Save button to save the current setting when you change sett...

Страница 24: ...f PTP time needs TAI time stamp please set this parameter to TAI format Time Zone 0 00H Set time zone offset for local time Unit is Hour H Range is between 12H and 12H Default value is 0 00H TAI UTC Offset 37 Set time offset between TAI and UTC Unit is Second s Range is between 32768s and 32767s Default value is 37s When system uses satellite or PTP signal as time source the current parameter will...

Страница 25: ...g Time DST working mode UTC Adjusting DST time according to UTC reference time LOCAL Adjust DST time according to local reference time Start Index 1st 2nd 3rd 4th 5th Last Set start parameters for DST starting time Set start index number to define week index in month The Daylight Saving Time DST will define by what month week day and time to start Start Weekday MON TUE WEN THU FRI SAT SUN Set star...

Страница 26: ...topping time Set stop index number to define week index in month The Daylight Saving Time DST will define by what month week day and time to stop Stop Weekday MON TUE WEN THU FRI SAT SUN Set stop parameters for DST stopping time Set stop weekday to define day index in week The Daylight Saving Time DST will define by what month week day and time to stop Stop Month JAN FEB MAR APR MAY JUN JUL AUG SE...

Страница 27: ...en The NTP setting screen will be shown as Figure 3 16 NTP Setting Screen Table 15 NTP Setting Items Parameters Description NTP Server Enable Disable Activate NTP server feature Enable Make NTP server start working Disable Make NTP server stop working NTP UTC Offset 0 00H Set time offset between NTP time stamp and UTC If NTP time stamp needs time offset please set this parameter Unit is Hour H Ran...

Страница 28: ... When it is Boundary mode PTP can automatic select one port as Master mode and another port as Slave mode Delay Measurement Mode E2E P2P Disable Set PTP Clock delay measurement mode E2E Set it works at E2E mode P2P Set it works at P2P mode Disable Don t enable delay measurement function Sync Interval 8 4 STOP Set PTP Clock sending sync message rate of Master mode 8 4 Set a number for interval If i...

Страница 29: ... 0 Priority1 0 255 Set working priority for PTP message of ETH0 Range is between 0 and 255 Default value is 0 Priority2 0 255 Set working priority for PTP message of ETH1 Range is between 0 and 255 Default value is 0 PTP Media 802 3 IPv4 Set the transmission protocol for PTP 802 3 PTP uses IEEE802 3 transmission protocol IPv4 PTP uses Ipv4 transmission protocol Rx Compensation 0ns Set the time del...

Страница 30: ...his function is suitable for the master clocks to coordinate time Press Save button to save the current setting when you change setting 3 5 5 Output Settings Press OUTPUT on the left navigation bar to show output setting screen Press Channel Group to select O1 O2 O3 O4 O5 output channel O1 channel is matched with FO interface of panel printing O2 channel is matched with DO 1 2 interface of panel p...

Страница 31: ...d PPH are pulse signal The interval is per second per minute and per hour sending one pulse Second Compensation 0s Set second compensation offset for O1 Unit is second s Range is between 999999999s and 999999999s Default value is 0s When SO PPS of SO is IRIG B time signal the parameter is also valid for its output signal PPS Compensation 0ns Set PPS compensation offset for O1 Unit is nanosecond ns...

Страница 32: ...meter is also valid for its output signal SO PPS PPS0 IRIG B0 PPM PPH Set output signal type for SO PPS of SO PPS0 Set output signal is PPS IRIG B0 Set output signal is IRIG B PPM Set output signal is PPM PPH Set output signal is PPH The PPS PPM and PPH are pulse signal The interval is per second per minute and per hour sending one pulse When SO PPS sets to IRIG B the IRIG B control parameter will...

Страница 33: ...nge is between 250000000ns and 250000000ns Default value is 0ns When SO PPS of SO is PPS PPM PPH time signal the parameter is valid for its output signal TOD Time Format UTC TAI Local Set reference time for TOD output signal of SO UTC Make output time working at UTC format TAI Make output time working at TAI format Local Make output time working at Local format When SO TxD of SO is TOD time signal...

Страница 34: ...PS compensation offset for O2 Unit is nanosecond ns Range is between 250000000ns and 250000000ns Default value is 0ns IRIG B Time Format UTC TAI Local Set reference time for IRIG B output signal of O2 UTC Make output time working at UTC format TAI Make output time working at TAI format Local Make output time working at Local format IRIG B Mode Even Odd Set IRIG B check code for O2 Even Use Even mo...

Страница 35: ... second compensation offset for O3 Unit is second s Range is between 999999999s and 999999999s Default value is 0s PPS Compensation 0ns Set PPS compensation offset for O3 Unit is nanosecond ns Range is between 250000000ns and 250000000ns Default value is 0ns IRIG B Time Format UTC TAI Local Set reference time for IRIG B output signal of O3 UTC Make output time working at UTC format TAI Make output...

Страница 36: ...output signal is PPS IRIG B4 Set output signal is IRIG B PPM Set output signal is PPM PPH Set output signal is PPH The PPS PPM and PPH are pulse signal The interval is per second per minute and per hour sending one pulse Second Compensation 0s Set second compensation offset for O4 Unit is second s Range is between 999999999s and 999999999s Default value is 0s PPS Compensation 0ns Set PPS compensat...

Страница 37: ...setting If select O5 in Channel Group the setting screen will be shown as Figure 3 22 Output Setting Screen O5 Table 21 Output Setting O5 Items Parameters Description IRIG B Second Compensation 0s Set second compensation offset for O5 Unit is second s Range is between 999999999s and 999999999s Default value is 0s IRIG B PPS Compensation 0ns Set PPS compensation offset for O5 Unit is nanosecond ns ...

Страница 38: ...e is between 3 0V and 12 0V Default value is 12 0V IRIG B Modulation Ratio 3 0 1 6 0 1 Set IRIG B output signal modulation ratio for O5 Step is 0 5 1 Range is between 3 0 1 and 6 0 1 Default value is 3 0 1 Press Save button to save the current setting when you change setting 3 5 6 Network Settings Press NETWORK on the left navigation bar to show network setting screen The network setting screen wi...

Страница 39: ...lex mode 1000M FX FDX 1000M Optical full duplex mode 1000M FX HDX 1000M Optical half duplex mode Press Save button to save the current setting when you change setting 3 5 7 TMS Settings Optional Press TMS on the left navigation bar to show TMS setting screen Press GOOSE channel to select GOOSE publisher and GOOSE subscriber channel The GOOSE publisher includes GOOSE P0 GOOSE P1 and work on ETH0 ET...

Страница 40: ...fined by GOOSE standard Default value is PTSTTR LLN0 GO gocb0 Provide IEC61850 ICD file the current default value is made by this ICD file GOOSE GoCBRef PTSTTR LLN0 GO gocb0 Set GCB reference of GOOSE message It is a string defined by GOOSE standard Default value is PTSTTR LLN0 GO gocb0 Provide IEC61850 ICD file the current default value is made by this ICD file GOOSE Dataset PTSTTR LLN0 dsGOOSE0 ...

Страница 41: ...iod unit is hour When the whole seconds of the current time is divisible by trigger period multiplied by 3600 the new GOOSE will generate vLan Priority 0 7 Set vLan priority of GOOSE message Range is between 0 and 7 Default value is 7 vLan CFI 0 1 Set vLan CFI information of GOOSE message Range is between 0 and 1 Default value is 0 vLan ID 0 4095 Set vLan ID information of GOOSE message Range is b...

Страница 42: ...publisher stop working APPID 0xXXXX Set APPID of GOOSE message Range is between 0x0000 and 0xFFFF Default value is 0x0002 APPID is a 32 bits data with hex display MAC 01 0C CD 01 XX XX Set MAC address of GOOSE message Default value is 01 0C CD 01 00 02 The first four parts of MAC address are standard value of GOOSE message If you find any network messages with these values the message is GOOSE mes...

Страница 43: ...PPM to trigger GOOSE message PPH Use PPH to trigger GOOSE message Trigger Period 0 255 Set period to send out GOOSE message Range is between 0 and 255 Default value is 0 The 0 means no data change and the non zero means system will send a new GOOSE when the current time at PPS PPM or PPH can be divisible by trigger period If trigger mode is PPS the trigger period unit is second When the whole seco...

Страница 44: ... message Range is between 0 and 1 Default value is 0 confRev 0 255 Set confRev value of GOOSE message Range is between 0 and 255 Default value is 1 ndsCom 0 255 Set ndsCom value of GOOSE message Range is between 0 and 255 Default value is 0 Press Save button to save the current setting when you change setting If select GOOSE S0 in GOOSE Channel the setting screen will be shown as Figure 3 26 GOOSE...

Страница 45: ...ndard Default value is PTSTTR LLN0 GO gocb0 Provide IEC61850 ICD file the current default value is made by this ICD file GOOSE Dataset PTSTTR LLN0 dsGOOSE0 Set GCB dataset of GOOSE message It is a string defined by GOOSE standard Default value is PTSTTR LLN0 dsGOOSE0 Provide IEC61850 ICD file the current default value is made by this ICD file Entry 0 31 Set the entry index of GOOSE message Range i...

Страница 46: ...0xXXXX Set APPID of GOOSE message Range is between 0x0000 and 0xFFFF Default value is 0x0002 APPID is a 32 bits data with hex display GOOSE GoID PTSTTR LLN0 GO gocb1 Set GCB ID of GOOSE message It is a string defined by GOOSE standard Default value is PTSTTR LLN0 GO gocb1 Provide IEC61850 ICD file the current default value is made by this ICD file GOOSE GoCBRef PTSTTR LLN0 GO gocb1 Set GCB referen...

Страница 47: ...is the first byte The 31 is the last byte Bit 0 7 Set the bit position of byte item Range is between 0 and 7 Default value is 0 The maximum bit of byte is 8 The 0 is the first bit The 31 is the last bit Press Save button to save the current setting when you change setting 3 6 System The WEB management system supports to manage Gateway Route information and to backup and restore configuration file ...

Страница 48: ...way information The gateway screen will be shown as Figure 3 29 System Screen The current routing table will be listed on the bottom of screen Press Add to add a new gateway for PTS DR200 time server Press Del to delete the selected route information 3 6 2 Route Press Route on the left navigation bar to manage Route information The route screen will be shown as ...

Страница 49: ...ion file The configuration screen will be shown as Figure 3 31 Configuration Screen Press Backup to backup configuration file and system will pop up a tip window let user to select a directory to save configuration file The name of configuration file is named by MAC address Press Restore to restore a configuration by WEB Before do it please select a file After press Restore the system will active ...

Страница 50: ...The firmware should be published by Official 3 6 5 SNMP Optional Press SNMP on the left navigation bar to manage SNMP feature The SNMP screen will be shown as Figure 3 33 SNMP Screen SNMP management supports to modify agent port and to add or delete V1 V2C and V3 access parameters The default agent port of SNMP is 161 The default access parameter of V1 V2C named public it only has read only permis...

Страница 51: ... Change Password Press Change Password on the left navigation bar to change password The change password screen will be shown as Figure 3 35 Change Password Screen Please Save to confirm the new password Please remember the new password If lost you could not login again 3 7 2 Reboot Press Reboot on the left navigation bar to reboot device The reboot screen will be shown as Figure 3 36 Reboot Scree...

Страница 52: ...Kyland Technology Shanghai Co Ltd PTS DR200 Time Server 50 Press Reboot to reboot device ...

Страница 53: ...nformation 15 Table 10 Sync Source Setting SAT1 17 Table 11 Sync Source Setting IRIG B1 19 Table 12 Sync Source Setting IRIG B2 20 Table 13 Sync Source Setting PTP 21 Table 14 Clock Setting 22 Table 15 NTP Setting 25 Table 16 PTP Setting 26 Table 17 Output Setting O1 29 Table 18 Output Setting O2 31 Table 19 Output Setting O3 33 Table 20 Output Setting O4 34 Table 21 Output Setting O5 35 Table 22 ...

Страница 54: ... Source Status Screen SAT1 12 Figure 3 6 Source Status Screen IRIG B1 13 Figure 3 7 Source Status Screen IRIG B2 13 Figure 3 8 Source Status Screen PTP 14 Figure 3 9 Clock Status Screen 15 Figure 3 10 Configuration Screen 16 Figure 3 11 Sync Source Setting Screen SAT1 17 Figure 3 12 Sync Source Setting Screen IRIG B1 19 Figure 3 13 Sync Source Setting Screen IRIG B2 20 Figure 3 14 Sync Source Sett...

Страница 55: ...n GOOSE S0 42 Figure 3 27 GOOSE Subscriber Screen GOOSE S1 44 Figure 3 28 System Screen 46 Figure 3 29 System Screen 46 Figure 3 30 Route Screen 47 Figure 3 31 Configuration Screen 47 Figure 3 32 Firmware Screen 48 Figure 3 33 SNMP Screen 48 Figure 3 34 Management Screen 49 Figure 3 35 Change Password Screen 49 Figure 3 36 Reboot Screen 49 ...

Отзывы: