Chapter 4 Hardware Mounting
4.1 Mounting requirements
KIEN6000 industrial Ethernet switch has a single body structure and can be directly
mounted on standard 35
㎜
DIN rail, or vertically mounted on the wall or inner wall of
cabinet with wall-mounting components.
Before mounting KIEN6000, fire check whether the working environment meets the
mounting requirements, including power supply requirement, adequate space, the
distance to other network equipments to be connected and whether other equipments
are available. Please ensure that the following mounting requirements are met:
1
.
Power supply requirement: standard KIEN6000 product uses redundant 24VDC
power supply (18VDC
~
36VDC).
2
.
Environment requirement: temperature -35
℃~
75
℃
, relative humidity 10
%~
95% (non-condensable).
3
.
Grounding resistance requirement: <5
4
.
Check whether optical fiber cable is laid properly and whether proper optical
fiber connectors are used according to the configuration requirements of the
contract.
5
.
Avoid exposure to direct sunlight and keep away from heat source or places with
strong electromagnetic interference.
6
.
Standard KIEN6000 product only provides DIN rail mounting components, so
users only need to get DIN rail available. If wall-mounting is necessary, users
need to purchase additional wall-mounting components. Moreover, users should
also get available screws, nuts and tools for wall mounting and ensure the
mounting is reliable.
7
.
Check whether cables and connectors necessary for mounting are available.