Figure 3-7 KIEN6000 network management wiring diagram
DIP switch for property setting
The DIP switch for setting of KIEN6000 has two positions, namely T and F. T is
used for setting redundant mode and common straight-through connection mode
of the two pairs of optical fiber interface. If position T shifts to ON, the two pairs
of optical fiber interface are set to common straight-through connection mode,
otherwise, they are set to redundant mode. F is used for setting the equipment to
local or remote when the optical fiber interface is in redundant mode. If T is in
OFF, when F shifts to ON, the equipment is set as local, otherwise it is set as
remote. The corresponding relation between specific positions of DIP switch and
equipment setting is shown in Table 3-2.
Table 3-2 Corresponding Relations between Specific Positions of DIP Switch and Equipment
Attribute
Position of DIP Switch
Position Sketch
Logic position
Attribute Implication
T
OFF
4
、
8 port set as straight-through
connection mode.
1 2
ON
T
F
F
OFF
1
、
2
port
set
as
common
straight-through connection mode.