Kyland Telecom
-17-
Power Gr ound
-
DC30V MAX.
+
Ter mi nal Locki ng Scr ews
Locki ng Scr ews f or Power Cabl es
24VA MAX.
Figure 3-6 External alarming lamp of alarming relay output
Network management interface
(
CONSOLE)
The network management interface of KIEN6000 is shielded RJ45 connector and
its interface communication standard is 3-wire RS232. Users can use a network
management cable with end bearing RJ plug and another end DB9F plug to
connect the network management interface of KIEN6000 with the 9-pin serial
port of the control computer. Operating the local management software provided
by KYLAND Telecom in the control computer allows configuration, enquiry and
management of the KIEN6000 equipment directly connected with the serial port
of the control computer. Connection of network management cable with the local
terminal network management interface to operate the network management
software provided by KYLAND Telecom in the control computer allows to
realize the configuration, enquiry and management functions of all KIEN6000
equipments within the entire network The wiring sequence for network
management interface of KIEN6000 and the 9-pin serial port of PC computer is
shown in Figure 3-7.