Meet Pedestal Structure Requirements
If a pedestal is going to be used, it must meet the following minimum requirements. Refer to Figure 3.
NOTE:
If the pedestal exceeds 3.28 ft (1 m), braces must be placed at 120° intervals. Sizing is based on Structural
Steel Tubing 60,000 psi (415 MPa) minimum yield.
Pedestal Height (A)
3.28 ft (1 m)
6.56 ft (2 m)
9.84 ft (3 m)
13.12 ft (4 m)
Tube OD (B)
5.0" (127 mm)
3.0" (76.2 mm)
5.0" (127 mm)
8.0" (203.2 mm)
Tube Wall Thickness (C)
0.25" (6.35 mm)
0.5" (12.7 mm)
Brace Height (D)
N/A
5.25 ft (1.60 m)
7.35 ft (2.24 m)
2.78 ft (9.12 m)
Brace OD (E)
N/A
2.25" (57.15 mm)
4.5"
114.3 mm
7.0" (177.8 mm)
Brace Thickness (F)
N/A
0.25" (6.35 mm)
Brace Angle(G)
N/A
25
°
Figure 3: Pedestal and Brace Dimensions
A
D
G
E
F
Brace
B
C
120°
Pedestal
Continued
Plan the Antenna Installation