Follow these steps to commission the ICM’s
built-in modem. This process is required to
determine the 1 dB compression point of the BUC
(block up-converter) (see Figure 44) and the
maximum transmit power.
NOTE:
This process takes about 30 minutes to
complete.
a.
Ensure the antenna has a clear, unobstructed
view of the sky.
b.
At the TracPhone V3-HTS web interface,
verify that the antenna is tracking the service
satellite and the system is online (see
c.
Click the
Support
tab and gather all of the
information listed on the Modem
Commissioning Worksheet (supplied in the
Welcome Kit).
d.
Click the link on the Support page to open the
modem commissioning wizard (see
Figure 46). Then log into the wizard:
NOTE:
Below is the default user name and password.
If you changed your user name or password in
“Customize the Web Interface” on page 22, you will
need to enter that unique name/password
combination.
• User Name:
admin
• Password:
password
Figure 44: BUC’s 1 dB Compression Point Determination
Power
Output
(dBm)
Power Input (dBm)
1 dB Compression Point
Gain
Linear Plot
Figure 45: Good Service Connection Indicated on Home Page
Figure 46: Support Page Link to Commissioning Wizard and Login
Commissioning Link
Commissioning Login
Commission the Modem