About the Setup Screen
2-23
KVAL 990-FX Operation Manual
7.
After satisfied, click the
Combine with Base
button to store the calibration.
Calibration Steps for the Lock Location
The
Lock Location Calibration
uses the X axis to tune the lock location.
for information about entering data. Below is a illustration on face plate
movement.
Lock Location Calibration
FIGURE2- 4.
Reference Door Lock
Lock Location
• The
Base
calibration sets the distances of the
LH and RH Stops
from the
Home Limit
as a reference.
•
6’-8'' to 8’ 0”:
Tunes the distance of the stops from the refer
-
ence (HOME) for LH and RH doors of each door length.
Note:
Door lengths may vary per option selection.
To start, run a known good lock cut at a standard location on
a Right Hand or Left Hand door.
Once the lock cut is completed, check the distance from the
top of the door to the center of the lock.
Note the measurement value and compare to specification.
If the lock location is correct, there is no need to perform
this process, If it is not correct, follow the instructions in
Measure