Kendrion Kuhnke Automation GmbH
Counter/Posi2, Counter2
54
11/25/2016
4.13.3.5 Digital I/Os
4.13.3.5.1 Zahler 1 Digitale Eingänge (Counter 1 Digital Inputs)
The variables indicate the status of the digital inputs.
Variable
Data type
Explanation
Input_0_0
BOOL
Digital Input 0
Input_0_1
BOOL
Digital Input 1
Input_0_2
BOOL
Digital Input 2
Input_0_3
BOOL
Digital Input 3
In_Output_0_0
BOOL
Status of Digital Output 0 (Reads the status)
4.13.3.5.2 Zähler 1 Eingangsflanken-Zeitstempel (Counter 1 Input Edge Timestamp)
The variables indicate the time, on which the status of the digital input has
changed. When the time measurement is started, depends on the mode of
operation.
(See also chapter 4.13.3.1 at page 49)
Variable
Data type
Explanation
Input_0_0_TS
UINT
Time stamp for Digital Input 0 (Hardware Trigger)
Input_0_1_TS
UINT
Time stamp for Digital Input 1 (Software Polling)
Input_0_2_TS
UINT
Time stamp for Digital Input 2 (Software Polling)
Input_0_3_TS
UINT
Time stamp for Digital Input 3 (Software Polling)
The time stamp is metered between frame- or DC-interrupts and signal
changes on the input in µs.
The value of the time stamp becomes to 0xFFFF, when no signal change
takes place between two frame- or DC-interrupts.