Kendrion Kuhnke Automation GmbH
Counter/Posi2, Counter2
53
11/25/2016
Variable
Data type
Explanation
Select_1
UINT
Selection which value of counter1 shall be displayed in
the variable "SelectedValue":
0
none
1
Vergleichswert (Compare value)
2
Vorwahlwert (Preset value)
3
Endwert (Max value) (Default:2.147.483.647)
4
Fangwert (Capture value)
5
Counter pulses/second
6
Revolutions per minute
128 Version info
SetValue_1
UDINT
Set value of counter 1 (source) to copy (operated by a
control bit) into a set value register (target)
4.13.3.4.2 Zähler 1 Istwerte (Counter 1 Actual Values)
These variables display the current counter value and the current set values.
The set values are represented multiplexedly in the variable
"SelectedValue" (Selection by Select_1).
Variable
Data type
Explanation
Counter_1
UDINT
Current value of counter 1
Selected_1
UINT
Selection of that value of counter 1, which is displayed
in the variable SelectedValue.
(Value of Select_1 read from the module)
0
none
1
Vergleichswert (Compare value)
2
Vorwahlwert (Preset value)
3
Endwert (Max value)
4
Fangwert (Capture value)
5
Counter pulses/second
6
Revolutions per minute
128 Version info
SelectedValue
UDINT
Selected current value of counter 1
Version info:
Byte
3
2
1
0
Explanation
Version #
Release
Level
Type code
Example
0x2
0x00
0x00
0x53
2
0
0
S