10. - Maintenance and storage
HR4004D-4504D
101
KN208JGB_C
Power harrow
- Remove lynch pin (1).
- Remove connecting piece (2).
- Loosen screw (3).
- Remove washer (4).
- Remove blades (5).
- Remove blade holder (6).
- Remove oil seal (7) using a screwdriver.
- Clean and lubricate oil seal housing.
- Fit new oil seal using special tool (8).
The oil seal is in place when tool (8) bottoms
against input shaft (9).
- Note oil seal mounting direction.
2
1
5
6
4
3
7
5
8
9
8