Spreading operation
161
B
AXIS
20.1
AXIS
20.1
AXIS
30.1 (W), AXIS 40.1 (W)
AXIS 50.1 W
Agitator does not operate
Check agitator drive See
Blockage of metering outlets by:
fertiliser clumps, damp fertiliser,
miscellaneous impurities (leaves,
straw, sack residues)
Clear blockages. Proceed as follows:
1.
Park tractor, remove ignition key
2.
Open metering slides
3.
Place collection vessel underneath
4.
Remove spreading discs
5.
Clean the outlet
from below
with a wooden pole or clean
the adjustment lever and push through the metering
opening,
6.
Remove foreign objects in hopper
7.
Install spreading discs, close metering slides
Fault
Possible cause/action