(1) Block
(A) “LOOSEN”
3. To sharpen the blades yourself, clamp the blade
securely in a vise.
Use a large mill file and file along the original bevel
until sharp.
4. To check the blade for balance, place a small rod
through the center hole. If the blade is not
balanced, file the heavy side of the blade until
balance is achieved.
5. Pass the spline boss through the plate, blade and 2
cup washers, and tighten the bolt.
NOTE :
• Make sure that the cup washer is not
flattened out or worn; this cause blade to
slip excessively.
Replace the 2 cup washers if either is
damaged.
(1) Spindle holder
(2) 2-Cup washer
(3) Spline boss
(4) Blade
(5) Bolt
IMPORTANT :
• Tighten the blade bolts from 103 to 118 N
⋅
m
(76 to 87 lbf
⋅
ft).
• The blade bolts have right hand threads.
Turn them counterclockwise to loosen.
• To prolong the service life of the blades,
reposition them as shown in the following
figure periodically.
(1) LH blade
(2) Center blade
(3) RH blade
3. Replacing the mower belt
1. Remove the mower deck from the machine.
(See DISMOUNTING THE MOWER DECK on page
26.)
2. Remove the left and right hand shield from the
mower deck.
3. Remove the tension pulley, and remove the belt.
4. To install a new belt, reverse the previous
procedure.
NOTE :
• Tighten the tension pulley bolt securely from
77.6 to 90.2 N
⋅
m (8.0 to 9.2 kgf
⋅
m, 57.1 to
66.5 lbf
⋅
ft).
(1) Tension pulley
(2) PTO clutch pulley
(3) Mower belt
(4) Bolt
(5) Shield
SERVICE AS REQUIRED
PERIODIC SERVICE
Z751KWi,Z781KWi,Z781KWTi
79
Содержание Z751KWi
Страница 3: ...OPERATOR S MANUAL 1SJGJ00001A01 READ AND SAVE THIS MANUAL MODELS Z751KWi Z781KWi Z781KWTi ...
Страница 15: ...SAFETY LABELS SAFE OPERATION 10 Z751KWi Z781KWi Z781KWTi ...
Страница 16: ...SAFE OPERATION Z751KWi Z781KWi Z781KWTi 11 ...
Страница 17: ...SAFE OPERATION 12 Z751KWi Z781KWi Z781KWTi ...
Страница 18: ...SAFE OPERATION Z751KWi Z781KWi Z781KWTi 13 ...
Страница 19: ...SAFE OPERATION 14 Z751KWi Z781KWi Z781KWTi ...
Страница 21: ...16 Z751KWi Z781KWi Z781KWTi ...
Страница 59: ...PERIODIC SERVICE CHART LABEL MAINTENANCE PERIODIC SERVICE CHART LABEL 54 Z751KWi Z781KWi Z781KWTi ...