Section 7
Specifications
72183227
8-2016/Rev 01
ORIGINAL INSTRUCTIONS
7-2
7.3
Pump Specifications
Minimum inlet water flow rate and pressure
2.0 gpm @ 57 psi (7.5 L/min @ 3.9 bar)
Systems should be sized for 150% of the pump capacity
Low inlet water pressure switch threshold
15 psi (1 bar)
Required inlet water temperature range
55º-70º F (12.7º-21.0º C)
Water temperatures exceeding this range will result in
seal life degradation. If seal life becomes unacceptable,
the addition of a chiller is recommended.
Drain water temperature and flow rate
212º F (100º C) at 0.9 gpm (3.4 L/min)
Output pressure range (dual pressure units)
1,000-55,000 psi (69-3,792 bar)
Crankcase reservoir capacity
1.2 gal (4.54 liter)
Recommended oil
Shell Morlina 100 Hydraulic Oil (ISO 100)
When operating in an ambient temperature greater than
86º F (30º C), a heavier oil is recommended
Other manufacturer’s equivalents can be
used
Motor type
TEFC (Totally Enclosed Fan Cooled)
See nameplate for machine specific ampacity and power voltage requirements.
Plant Air
The facility compressed air connection should provide clean, dry air regulated to between 90 and
120 psi (6.2 and 8.3 bar).
The following table provides specifications for each ISO air quality classification. KMT
recommends adherence to Quality Class 4.
Table 7-2
ISO Air Quality Classifications
ISO Quality
Class
Maximum
Particle Size
(microns)
Maximum Pressure
Dew Point
(water @ 100 psi)
Maximum Oil Content
(Mg/m
3
)
1
0.1
-94° F (-60° C)
0.01
2
1
-40° F (-40° C)
0.1
3
5
-4° F (-20° C)
1
4
15
+38° F (+3° C)
5