Section 5
Service Procedures
72183211
8-2016/Rev 01
ORIGINAL INSTRUCTIONS
5-11
5.5
Minor Maintenance Kit
The minor maintenance kit must be installed every 500 hours. Use the following procedure to
install the minor maintenance kit. The minor maintenance kit contains the following replacement
components.
Table 5-3
Minor Maintenance Kit
72185099
Part Number
Component
Subassembly
72185117
Dynamic seal
Dynamic Seal Assembly
72185125
Rod seal
72185133
Inlet poppet
Inlet Check Valve Assembly
72185141
Inlet poppet spring
72185149
Sleeve
72185167
Discharge poppet guide
Discharge Check Valve Assembly
72185185
Discharge poppet
72185192
Discharge poppet seat
72185200
Discharge poppet spring
20434082
O-ring
End Cap
05122007
O-ring
High Pressure Cylinder
20434082
O-ring
Subplate Adapter
10074383
O-ring
72185208
Rod seal
72185226
Retaining ring
72185234
Poppet/Seat Assembly
Pressure Control Valve Assembly
10149029
320 grit paper
10087385
FML-2 food grade grease
49832199
JL-M anti-seize