Section 6
Troubleshooting
72183219
4-2016/Rev 0
ORIGINAL INSTRUCTIONS
6-3
Table 6-1
TRILINE™ Troubleshooting Guide
Malfunction
Indication
Comments
3.
Pump is vibrating and/or
making noise
Missing or worn anti-
vibration mat
Install the pump on an anti-
vibration mat.
Replace the existing anti-
vibration mat.
Improper belt tension or
failed belts
Properly adjust the belt tension.
See Section 5, Tensioning and
Aligning the Belt Drive.
Replace the belts. See Section
5, Replacing the Belts.
Dynamic seal failure
Install a Minor Maintenance
Kit. See Section 5.
Check valve failure
Install a Minor Maintenance
Kit. See Section 5.
Crankcase failure
Replace the crankcase.
Incorrect motor rotation
Check motor rotation and
correct if necessary.
Loss of electrical power leg
Verify incoming power is on all
three legs.
Check the wiring and fuses.
4.
Pump does not start
Pump is not wired
Verify the customer-supplied
service disconnect is on and all
fuses are properly sized and
functional.
Verify the motor starter
disconnect is turned on.
Check for loose wiring and
correct if necessary.
Tripped circuit breaker in
control box.
Reset circuit breaker.