Section 6
Troubleshooting
72183219
4-2016/Rev 0
ORIGINAL INSTRUCTIONS
6-7
Table 6-1
TRILINE™ Troubleshooting Guide
Malfunction
Indication
Comments
Pump does not produce the
desired pressure, continued
Failed dynamic seal
May be an indication of a
failed plunger, improper tie
rod loading, elevated inlet
water temperature or lack of
cooling water due to clogged
cooling ports.
Inspect plunger and dynamic
seal carrier to determine if
repairs require a Minor or a
Major Maintenance Kit. See
Section 5.
Leaking high pressure
cylinder
Inspect the cylinder(s) for
cracks. If detected, install a
Major Maintenance Kit. See
Section 5.
Inspect the contact surfaces on
the dynamic seal carrier and the
check valve body for spalling,
erosion or damage. If detected,
install a Major Maintenance Kit.
See Section 5.
Failed high pressure tubing
and/or connection(s)
Check high pressure
connections for proper
installation and torque.
Check tubing and fittings for
cracks and replace as necessary.
Check tubing around high
pressure connections for
deformation and replace tubing
as necessary.
Clogged inlet water filters
Replace filters. See Section 5,
Low Pressure Filter
Maintenance.
Failed or improperly
calibrated high pressure water
gauge
Recalibrate the gauge.
Replace the gauge.
Excessive tubing length
between the pump and the
pressure gauge
Call KMT Technical Services.