3 SERVICE WORK ON THE CHASSIS
22
3.28
Connecting the negative cable of the 12 V battery
D06084-10
–
Connect negative cable
1
of the 12 V battery.
Guideline
Screw, battery termi-
nal
M5
2.5 Nm
(1.84 lbf ft)
Contact disk
A
must be mounted under screw
2
and
cable lug
3
with the claws toward the battery terminal.
D06082-11
–
Position the 12-V battery in the battery compartment.
–
Insert battery cover
4
.
–
Mount and tighten screw
5
.
3.29
Charging the 12 V battery
Warning
Risk of injury
12 V batteries contain harmful substances.
–
Keep 12 V batteries out of the reach of children.
–
Keep sparks and open flames away from 12 V batteries.
–
Only charge 12 V batteries in well-ventilated rooms.
–
Maintain a minimum clearance from inflammable materials when charging 12 V batteries.
Minimum clearance
1 m (3 ft)
–
Do not charge deeply discharged 12 V batteries if the charge is already below the minimum voltage.
Minimum voltage before the start of the charge
9 V
–
Dispose of 12 V batteries with less than the minimum voltage correctly.
Note
Environmental hazard
12 V batteries contain environmentally hazardous materials.
–
Do not dispose of 12 V batteries as household waste.
–
Dispose of 12 V batteries at a collection point for used batteries.