F U N C T I O N T E S T S
Measuring flow rate of hot beverage
1. Switch machine ON.
2. Place a measuring beaker under
outlet.
3. Insert an espresso capsule in
capsule holder.
4. Insert capsule holder and push it
down.
5. Set selection lever at position
)
(hot).
6. Start timer simultaneously.
7. Wait until 40 ml coffee has flown in
the measuring beaker.
8. Stop timer.
The measured time m ust be within
9 15 sec.