F U N C T I O N T E S T S
Heating up time
Priming of fluid system
If the heating up
time is more than
40 sec., change the main
pcb.
1. Plug into mains and press power
button.
2. Check the heating up time (time until
power button stops blinking). The
time must be not more than 40 sec.
Prime the fluid sys-
tem before pressure
test and flow rate meas-
urement.
3. Check resp. fill water tank.
4. Place a recipient under outlet.
5. Set selection lever at positions
(
(cold) and
)
(hot) separately for
about 10 sec. to prime the fluid
system.