T R O U B L E S H O O T I N G
4 Plug into mains
and switch ON
machine
4.2 Indicator (LED) flashes red
3 times a second (error mode)
YES a) Check if NTC temperature
sensor is functional
NO Replace NTC tempera
ture sensor
.
YES Go to point b)
YES b) Check if electrical wires
are functional
NO Go to point 4.3
YES Replace PCB assembly
NO Replace defective(s)
wire(s)
.
4.3 Machine is working without
capsule holder
YES Replace the extraction head
NO Go to point 4.4
4.4 Machine is hissing if valve
handle is in middle position
YES Replace the extraction head
NO Go to point 5
4.5 No cup lighting
YES Check if cable connector and
cup lighting wiring are functional
NO Go to point 5
YES Replace cup lighting or
PCB assembly
.
NO Fix lose connection(s)
5 Checks while
preparing a beverage
5.1 No extraction possible (no
water at coffee outlet)
YES a) Water tank is empty?
YES Fill water tank
NO Go to point b)
YES b) Water tank is correctly
inserted?
YES Go to point c)
NO Insert water tank
correctly
YES c) Filter is blocked or not in
right position
YES Replace filter
.
NO Go to point d)
YES d) Fluid system is empty?
YES Prime the fluid system
without capsule
.
NO Go to point e)
YES e) Fluid system is blocked by
scale?
YES Descale the fluid system
NO Go to point f)
YES f) Injector is still clogged after
descaling?
YES Deblock the injector
NO Replace the extraction
head
.
5.2 Hot water temperature is too
low (less than 70°C / 158 °F)
YES a) Check if NTC temperature
sensor is functional
NO Change NTC tempera
ture sensor
.
YES Go to point b)
YES b) Fluid system is scaled?
YES Descale the fluid system
NO Replace PCB assembly
YES c) Valve malfunction?
YES Replace the extraction
head
.
NO Go to point d)
YES d) Flow rate of pump out of
range?
YES Replace the pump
.
NO Go to point 5.3
Check
procedure
Symptoms
Action / repair work
Further action /
repair work
Содержание KP 5000
Страница 26: ...R E P A I R Removing housing back 2 Loosen 6 security screws on the housing back D 3 Remove housing back...
Страница 60: ...R E P A I R 12 Release latch with screwdriver and pull off locking handle r 13 Remove 2 screws n...
Страница 63: ...W I R I N G D I A G R A M W I R I N G D I A G R A M Wiring diagram for 100V 120V 230V mains voltage...