R E P A I R
7. Cut through hot water pressure hose (h) like pictured above.
8. Pull cold water pressure hose (g) through rubber bushings.
9. Loosen screw (i) and remove thermoblock with insert (j).
10. Check if support on centerpart has melting marks due to overheating of the defect
thermoblock.
Do not damage
cold water pressure
hose with cutter.
The machine is irreparable if a new thermoblock cannot be screwed on
centerpart properly due to melting marks.