R E P A I R
Fastening a shaky extraction head
After impact stress, falling down, holding the locking handle and lifting the machine etc.
the latch and screw connections between extraction head and centerpart can become
loose.
1. Remove housing right and left.
2. Check if the 2 screws (n) are present.
3. Replace or fasten screws.
4. Check if extraction head is steady now.
The extraction head
is mounted on the
centerpart with 2 addi-
tional screws.
Use only torx
screws 3 x 15 mm
for thermoplastics.