R E P A I R
Replacing thermoblock
1. Remove housing right with spacer and housing left first
.
2. Unplug flat receptacles from thermoblock (Z).
3. Unplug NTC connector from main PCB.
4. Remove NTC cable from cable guides in centerpart.
Pay attention to
residual water flow-
ing out from the ther-
moblock.
The flat receptacles have a special connector latching.
Press down lever at first, then pull receptacle.