![Krone Round Pack 1250 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/krone/round-pack-1250/round-pack-1250_original-operating-instructions_2004825040.webp)
V - 6
Basic Settings and Operation
CP101260
3
1
1
2
3
• Undo the screws (1) of the bearing housing of the (3)
blade control shaft (2) on the left-hand side of the
machine.
• Undo the screws (1) of the bearing housing of the (3)
blade control shaft (2) on the right-hand side of the
machine.
5.3.6 Setting Blade Control Shaft
If the blades are worn out, the blade control shaft (1) can
be reset. For this, the bearing housings of the blade
control shaft must be loosened; after that, the blade
control shaft can be aligned to the rotary shaft.
The gap (a) must be at least 5 mm wide.
With new blades, set the blade control shaft
back.
CP100093-1
1
a
CP101253
1
2
CP100010
2
4
1
2
2
3
The blade control shaft (1) can be aligned using the slots.
• Undo the lock nuts (3) and align the blade control shaft
(1) to the cutting rotor with the setting screws (4).
• Carry out the alignment equally on both sides.
• Tighten the mounting screws (2) of the bearing housing
on both sides of the machine.
Содержание Round Pack 1250
Страница 20: ...II 10 Safety ...
Страница 34: ...IV 6 Use ...
Страница 61: ...V 27 Basic Settings and Operation ...
Страница 62: ...V 28 Basic Settings and Operation ...
Страница 84: ...VIII 16 Control unit Comfort ...
Страница 96: ...IX 12 Maintenance VP100101 1 Z 2a 9 H L 4 a1 11 12 I II 5 3 3 2b a2 H L 6 Z m in 0 2a 2b 7 7 ...
Страница 111: ...IX 27 Maintenance ...
Страница 112: ...IX 28 Maintenance ...
Страница 114: ...X 2 Winter Storage ...
Страница 122: ...XII 6 Faults Causes and Remedy ...
Страница 134: ...A 12 Appendix ...
Страница 135: ...A 13 Appendix ...