6.3 Installing the automatic spray gun
Changing the installation position of the automatic spray gun
The automatic spray gun can be mounted on both sides on the retaining bolts in order to
change the installation position.
Fig. 2: Installing the automatic spray gun
1.
Slide the automatic spray gun ( Fig. 2/1) with the respectively designed drill hole over the
retaining bolt ( Fig. 2/3).
2.
Fix retaining bolt with installation screws ( Fig. 2/2).
3.
Ensure proper earth connection of the automatic spray gun.
6.4 Connecting the automatic spray gun
See also (
Chapter 6.5 ‘Connection scheme’ on page 19
WARNING!
Danger of injury due to improper connection!
When the material supply is pressurised, e.g. from pressure containers or with pumps, the
range of the fluid jet can increase by a multiple in case of atomiser air failure. This presents a
hazard to people and property.
–
Make sure that the material supply and the control air are interrupted if the atomiser air
pressure drops off quickly.
–
It is recommended to regulate the atomiser air pressure via a filter pressure reducer.