Do not use sharply abrasive, chemically aggressive, very hot or very cold spray fluids without
first consulting with and receiving approval from Krautzberger GmbH.
n
Adhere to the spray fluid manufacturer's safety data sheets.
n
Only operate the automatic spray gun while adhering to the values specified in (
13 ‘Technical data’ on page 43
n
Only operate the automatic spray gun after proper fastening on a suitable carrier construction.
n
Do not hold the automatic spray gun in your hand during operation.
n
Never point the compressed air at living beings.
n
Adhere to the operating manuals for the respective components.
7.3 Shutting down
7.3.1 Temporary shut-down
End the spray process by switching off the control air (connection "St").
The atomiser air (connection "Z") is automatically closed in the automatic spray gun.
7.3.2 Long-term shut-down
1.
Close the air supply for control air and atomiser air (
Chapter 6.5 ‘Connection scheme’
).
2.
Close the material supply and switch off the pump if necessary.
3.
If necessary, clean the automatic spray gun (
Chapter 8.3 ‘Cleaning the automatic spray
).
7.4 Operation
To achieve optimal results, adhere to the following:
–
Rinse the automatic spray gun with cleaning products before commissioning.
–
Too-high air pressure causes unnecessarily high air consumption and too-strong atomi-
sation of the spray fluid.
–
Too-low air pressure produces an unsatisfactory spray pattern.
–
Select the lowest possible fluid pressure.
Automatic spray gun M14
ENGLISH
■
200-0153
GB–23