background image

OBSOLETE

Instruction Sheet

E

1997 Nordson Corporation

All rights reserved

237 368A

Issued 3/97

Manual 10-29

P/N 237 368A

Iso-Flo

r

 and WM-1 Manual Gun Dolly System

Assembly

WARNING:  Allow only qualified personnel to perform the
following tasks.  Follow the safety instructions in this document
and all other related documentation.

This system consists of the following parts:

S

Iso-Flo HD Voltage Block assembly

S

WM-1 manual gun with hoses

S

electrostatic power supply

S

electrostatic cable

S

dolly

S

attaching hardware

See Figure 1 

and refer to the parts list to assemble the system onto the

dolly.

WARNING:  To prevent injury to personnel and damage to
equipment, read and understand each manual included with
this system.

1. Open the Iso-Flo door.

2. Make sure that the electrostatic voltage is off.

3. Supply water through the fluid inlet.  Check for leaks.

4. Turn on the compressed air to the Iso-Flo system.  Verify that the

setting is 5–7 bar (80–100 psi).

5. Turn on the fluid inlet pressure.  Verify that the setting is 5–10.3 bar

(80–150 psi).

6. Trigger the WM-1 gun until water comes out.

1. Introduction

2. Assembly

3. Initial Startup

Отзывы: