14
OIE 12en Edition 2019-02
Operating Instructions
Installation
In
s
ta
lla
ti
o
n
a
n
d
r
e
m
o
v
a
l
1. Create a control cabinet section, see Fig. 3, page 13.
2. When the space is limited, remove the housing cover
6
and seal with cable entries
5
.
3. Slide the front frame
2
from behind onto the electronic unit
1
.
4. Place the electronic unit with the front frame from the front into the control cabinet section,
see Fig. 3.
5. Slide the sealing frame
4
from behind onto the electronic unit, whereby the sealing surface has to
point to the front.
6. Fasten the front frame and sealing frame using the 4 supplied screws and lock washers. Tighten the
screws carefully.
Tightening torque: 1 Nm
The electronic unit is ready for the connection of the cables.
Wall mounting
For wall mounting a universal mount is available as an accessory, see "Accessories mounting",
page 54.
Prerequisite:
□
Universal mount is mounted to the wall
□
All cables have been cut to length and connected
Aids
□
KRAL tool set
1. Slide the electronic unit
1
into the universal mount
2
.
2. Fasten the electronic unit using the supplied screws, washers and wedge lock washers.
The electronic unit is ready to operate after the power supply has been switched on.
Pipe mounting/mounting on volumeter
The electronic unit can be mounted to the pipe or on the volumeter by means of the universal mount and
the corresponding fixing kit. The required fixing kit is available as an accessory, see "Accessories
DANGER
Risk of death resulting from electric shock.
►
Ensure that the power supply is disconnected.
►
The electronic unit may only be connected by an authorized electrician.
1
Electronic unit
2
Universal mount
Fig. 4
Universal mount for wall mounting
1
2