22
OIE 12en Edition 2019-02
Operating Instructions
Connection assignments
T
e
c
h
n
ic
a
l
d
a
ta
Pulse outputs
The data logger can be connected to these connections, see "Data acquisition accessories", page 59.
Relay outputs
Temperature sensor Volumeter A
Temperature sensor Volumeter B
24 V DC connection
Different power supply units are available as accessories, see "Accessories electrical connection",
page 56. These are connected here.
Serial interface
Connection
Function
Terminal
Pulse output 1
Signal
1
Gnd
2
Pulse output 2
Signal
34
Gnd
35
Connection
Function
Terminal
Relay output 1:
Bypass valve or filling valve
NO contact
NO
9
Switching contact
10
NC contact
NC
11
Relay output 2:
Collective error message
NO contact
NO
42
Switching contact
43
NC contact
NC
44
Connection
Function
Terminal
Temperature sensor Volumeter A
Signal
3
Common
4
Common
5
Connection
Function
Terminal
Temperature sensor Volumeter B
Signal
36
Common
37
Common
38
Connection
Terminal
+24 V DC
12
Gnd
13
Interface
Function
Terminal
RS 485
A
14
B
15
RS 232
TxD
23
RxD
24
Gnd
25