2.20 Maximum temperature Volumeter
The highest permissible operating temperature of
the volumeter is specified in this menu. This
temperature is limited mainly by the selection of
the pick up. Exceeding results in a corresponding
error message.
2.21 Reset to factory settings
This function resets all the settings to the state of
delivery.
Menu 3: Output settings
Menu 3 allows adjustment of the outputs in
accordance with the requirements of the
measuring task. All the settings can only be
changed after the password has been entered.
3.01 Function analog output
The function of the analog output can be
specified here. Either 2 units 4-20 mA or 2 units
0-10 V analog outputs are available.
3.02 Allocation analog output 1
A total or rate value can be assigned freely to the
Analog output 1.
Available values:
□
Q Rate consumption A-B or A+B
□
QA Rate current flow Volumeter A
□
QB Rate current flow Volumeter B
□
T1 Total consumption A-B or A+B
□
TA1 Total flow Volumeter A
□
TB1 Total flow Volumeter B
3.03 Scale analog output 1
The scale of the analog output is used to set the
maximum value. The maximum value is set
slightly higher than the highest possible occurring
flow rate. If the value "0" is entered here, Analog
output 1 is deactivated, so that 0 V or 4 mA
respectively is output.
3.04 Allocation analog output 2
A total or rate value can be assigned freely to the
Analog output 2.
Available values:
□
Q Rate consumption A-B or A+B
□
QA Rate current flow Volumeter A
□
QB Rate current flow Volumeter B
□
T1 Total consumption A-B or A+B
□
TA1 Total flow Volumeter A
□
TB1 Total flow Volumeter B
3.05 Scale analog output 2
The scale of the analog output is used to set the
maximum value. The maximum value is set
slightly higher than the highest possible occurring
flow rate. If the value "0" is entered here, Analog
output 2 is deactivated, so that 0 V or 4 mA
respectively is output.
2.20 Setting
Maximum temperature
Volumeter:
125 °C
2.21 Setting
Reset to
factory settings:
No
3.01 Setting
Function
Analog output:
4-20 mA
3.02 Setting
Allocation
Analog output 1:
Q
3.03 Setting
Scale max.
Analog output 1
10.0 l/min
3.04 Setting
Allocation
Analog output 2:
QA
3.05 Setting
Scale max.
Analog output 2
100.0 l/min