Operating Instructions
OIE 12en Edition 2019-02
13
Installation
In
s
ta
lla
ti
o
n
a
n
d
r
e
m
o
v
a
l
Installation in the control cabinet
The electronic unit can be mounted in control cabinets having a sheet thickness of 0.5 – 5 mm by using
the supplied mounting frame. The mounting frame consists of a front frame
2
and a sealing frame
4
, see
Fig. 2, page 13.
When the space is limited, mounting is also possible without a housing cover
6
and seal with cable
entries
5
An adapter set is available for converting BEM 4U to the electronic unit BEM 500, see "Adapter set for
conversion of BEM 4U to BEM 300/500", page 55.
Required minimum mounting depth: 80 mm
Dimensions of front frame:
□
Height:
145 mm
□
Width:
145 mm
□
Depth:
12 mm
Aids:
□
KRAL tool set
1
Electronic unit
2
Front frame
3
Control cabinet
4
Sealing frame
5
Seal with cable
entries
6
Housing cover
Fig. 2
BEM 500 control cabinet installation
a
117 mm
b
117 mm
Fig. 3
Control cabinet section
1
2
3
4
5
6
a
b