MAINTENANCE REQUIREMENTS
1. The appliance should be inspected at least once
a year by a professional service person.
NOTE: INSTALLATION AND REPAIR SHOULD BE
DONE ONLY BY A QUALIFIED SERVICE PERSON. THE
APPLIANCE SHOULD BE INSPECTED BEFORE USE
AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE
PERSON. MORE FREQUENT CLEANING MAY BE
REQUIRED DUE TO EXCESSIVE LINT FROM
CARPETING, BEDDING MATERIALS, ETC. IT IS
IMPERATIVE THAT CONTROL COMPARTMENTS,
BURNERS AND CIRCULATION AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
2. The compartment below the firebox (behind the
lower grill) must be cleaned at least once a year,
more frequent cleaning may be required due to
excessive lint from carpeting, bedding materials,
or other fibrous materials. It is imperative that
the burner be cleaned once a year.
FAN:
The fan should be disconnected from electrical
current, and cleaned (vacuumed) every six months.
The bearings are sealed and require no oiling.
VENT SYSTEM:
Annual examination of the venting system by a
qualified agency is required.
IF THE VENT-AIR INTAKE SYSTEM IS
DISASSEMBLED FOR ANY REASON, REINSTALL
PER THE INSTRUCTIONS PROVIDED WITH THE
INITIAL INSTALLATION.
1. Remove the upper grill.
2. Remove the glass from the front of the unit.
For easier access, remove the logs.
3. Cover the millivolt board system.
4. Loosen the nuts securing the baffle at the back
of the firebox and remove the baffle.
5. Examine proper sealing of the vent system.
6. Replace the baffle and secure the nuts.
7. Replace the logs, glass and upper grill.
The flow of combustion and ventilation air must not
be obstructed.
IMPORTANT: ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE.
CAUTION: LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
MILLIVOLT BOARD SYSTEM:
1. Annual cleaning of the burner is required. The log
plate and burner tube may be removed for easier
access.
2. Remove the logs and log plate.
3. Remove the burner tube by lifting it up off the tabs
and sliding it off the burner orifice.
4. Visually check for blocked port holes, especially
near the pilot. Blocked port holes may cause
delayed ignition.
5. Replace components by following the instructions
found in section ‘N’ Millivolt Board Removal /
Installation of this manual.
Millivolt Board
6. Visually check the pilot light and burner when they
are burning. See Figures above and below. The
flames should be steady, not lifting or floating.
Burner Orifice
Pilot
GLASS CLEANING & REPLACEMENT:
•
Clean glass only when cool and only with non-
abrasive cleansers.
•
Do not operate this fireplace with the glass/frame
assembly remove, cracked or broken.
•
The glass assembly, Part #700-07T, shall only be
replaced as a complete unit, as supplied by
Hussong Mfg. Co., Inc.
•
Replacement of the glass & gasket assembly, Part
#700-07T, must only be performed by a licensed or
qualified service person. DO NOT SUBSTITUTE
MATERIALS.
•
Do not strike or slam glass door assembly.
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF
COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND
OTHER FLAMMABLE VAPORS AND LIQUIDS.
Page 22