background image

REPLACEMENT PARTS 

 

Replacement parts are available through your local dealer. Contact them for availability and pricing. 

 
MILIIVOLT BOARD AND PARTS 
 
WDM-800   Millivolt Board - Natural Gas  

700-203  

Manual Shut off Valve 

WDM-801   Millivolt Board - LP Gas  

700-213B   18" Flexible Gas Line - Black 

700-023  

On/Off Rocker Switch  

700-224  

3/8" Flexible Gas Line - Valve to Burner connection 

700-057  

Honeywell valve- Natural Gas  

700-242  

Natural Gas orifice #42 

700-057-1   Honeywell valve - LP Gas  

700-255  

LP Gas orifice #55 

700-059  

Thermocouple  

700-075  

Natural Gas conversion cap 

700-060  

Flexible Pilot Tubing (Valve to Pilot)  

700-076  

LP Gas conversion cap 

700-063  

Pilot/Generator/Thermocouple - Natural Gas  

OCK-H42   Natural Gas Conversion Kit 

700-063-1   Pilot/Generator/Thermocouple - LP Gas  

OCK-H55   LP Gas Conversion Kit 

700-083  

Piezo Ignitor w/ wire  

OKA-035   Burner tube 

700-092  

Millivolt Generator 

 
 
FAN - REPLACEMENT ONLY 
 
WDM-028   Fan Kit with Temperature limit switch 
404-4  

Limit Switch Assembly 

600085  

Speed Control 

 
 
REMOTE CONTROLS / THERMOSTAT 

UPPER GRILLS 

 
796-2  

Remote Control with thermostat 

936-200  

Black Upper Grill 

797-1  

Remote Control  

936-20B  

Brass Upper Grill 

700-038  

Wall-mount Thermostat  

936-20C  

Chrome Accent Upper Grill 

 

 

301-120  

Chrome Upper Grill 

 

 

VF-200  

Brass Accent Upper Grill 

 
 
GLASS & GLASS GASKET  

LOWER GRILLS 

 

 

700-07T  

17" x 30" Glass with gasket 

936-201  

Black Lower Grill 

500-404  

1 1/8” Glass gasket w/ adhesive 

936-21B  

Brass Lower Grill 

 

 

936-201C   Chrome Accent Lower Grill 

  

302-120 

 

Chrome 

Lower 

Grill 

 

 

VF-201 Brass Accent Lower Grill 

 
 
LOG SET & REFRACTORY PANELS 

 

 
WDM-50A    Log Set  
WDM-900A   3 pc. refractory panel set 
 
 
MISC.  

VALANCE / VALANCE TRIM 

 
617 

44” Lintel Iron  

936-005  

Arched Valance (no glass) 

 

 

936-REC 

Rectangular Valance (no glass) 

 

 

500-936  

Brass Trim - Arched Valance only 

 

 

500-936C   Chrome Trim - Arched Valance only 

 
 
 
 
 
This 

appliance 

tested 

certified 

by: 

 

      Manufactured 

by: 

 
OMNI-Test 

Laboratories, 

Inc. 

 

      Hussong 

Mfg. 

Co., 

Inc 

5465 

SW 

Western 

Avenue 

 

       204 

Industrial 

Park 

Drive 

Beaverton, 

Oregon 

97075 

 

       Lakefield, 

MN 

56150 

 
 
#56101 ‘ WINDOM’ - Direct Vent Gas Fireplace 

 

www.kozyheat.com 

Page 27

Содержание windom 56101

Страница 1: ...must be performed by a qualified installer service agency or the gas supplier MODEL 56101 WINDOM DIRECT VENT GAS FIREPLACE INSTALLATION AND OPERATING MANUAL This appliance may be installed in an afte...

Страница 2: ...ed heating appliance or equipment The sign shall read in print size no less than inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state of local gas inspector of the...

Страница 3: ...S 10 REMOVE THE GLASS ASSEMBLY 11 DIRECT VENT CHIMNEY INSTALLATION 11 FAN INSTALLATION 12 13 GAS LINE SPECIFICATIONS 14 15 SECURE THE MILLIVOLT BOARD 15 LOG INSTALLATION 16 THERMOSTAT WALL SWITCH REMO...

Страница 4: ...Current Edition SPECIFICATIONS Height front 32 Height back 30 1 8 Front width 36 Back width 23 3 8 Depth 11 Flue size 4 exhaust 6 5 8 combustion air intake PASS THRU WALL THICKNESS The Dura Vent DV G...

Страница 5: ...ance and to replace any part of the control system and any gas control which has been under water CONSULT YOUR LOCAL OR NATIONAL INSTALLATION CODES TO ASSURE THAT ADEQUATE COMBUSTION AND VENTILATION A...

Страница 6: ...IPE TO FINISHED WALL REQUIRED 1 Clearance at sides 1 Clearance at sides 2 1 4 1 54 3 4 38 5 8 KOZY HEAT CORNER CABINET INSTALLATION MODEL 56101 WINDOM CORNER CABINET DIMENSIONS FIGURE 2C MODEL 56101 W...

Страница 7: ...MPORTANT Consult the local and national installation codes to assure that adequate combustion and ventilation air is available MINIMUM MAXIMUM VENTING REQUIREMENTS Minimum vertical rise maximum horizo...

Страница 8: ...ide inside corner 12 F 7 Meter Regulator not to be installed above within 3 ft horizontally from the center line of the regulator 8 Service regulator vent outlet 3 ft radius 9 Electrical box 3 ft G DO...

Страница 9: ...tion cap Maximum horizontal run 14 ft 1 4 incline for each horizontal foot of chimney must be maintained WALL THIMBLE 6 22 3 8 TO CENTER OF VENT PIPE 26 TO TOP OF VENT PIPE 1 CLEARANCE AT THE TOP FOR...

Страница 10: ...rmation WHEN VERTICALLY TERMINATING THE MINIMUM CHIMNEY HEIGHT ABOVE THE ROOF LINE IS DETERMINED BY THE FOLLOWING CHART Roof Pitch Minimum Chimney Height Roof Pitch Minimum Chimney Height Flat to 6 12...

Страница 11: ...in compliance with the guidelines on page 6 of this manual 2 Determine the width depth and height of the optional hearth NOTE A hearth is not required If a hearth is desired combustible materials may...

Страница 12: ...ir around the unit Air enters the unit at the lower grill and exits at the upper grill Blocking these passages may result in overheating the fireplace creating a potentially hazardous situation 6 Plac...

Страница 13: ...age from the firebox and set aside HORIZONTAL VERTICAL VENTING APPLICATIONS 1 INSTALL THE CHIMNEY SYSTEM FOR YOUR VENTING CONFIGURATION FOLLOWING THE CHIMNEY MANUFACTURERS INSTRUCTIONS INCLUDED WITH T...

Страница 14: ...includes 1 Right and left fan assemblies with fans with temperature control switch 2 Components Package Speed control with mounting bracket nut knob installation instructions NOTE To wall mount the s...

Страница 15: ...wiring with ground through the romex connector installed in the electrical box and wire to the receptacle 6 Secure receptacle into the electrical box 7 Install the cover onto the electrical box and s...

Страница 16: ...ffixed to the flexible tubing for additional installation instructions and warnings NOTE For high altitude installations consult the local gas distributor or the authority having jurisdiction for prop...

Страница 17: ...rom the gas supply piping system during any pressure testing of that system at test pressures in excess of psi NOTE The appliance must be isolated from the gas supply piping system by closing its indi...

Страница 18: ...remaining base logs W6 W7 into the center of the burner as shown Natural Gas models Push the logs back against the burner tube 3 Carefully place the rock wool embers as desired onto the logs and burne...

Страница 19: ...es from the top bottom terminals on the gas valve Follow instructions included with the remote control Remote Control Wiring Diagram CAUTION DO NOT CONNECT HIGH VOLTAGE 115V WIRE TO THE GAS VALVE REMO...

Страница 20: ...embly to the fireplace by pulling the two spring loaded handles located under the firebox out and up over the latch brackets Release locking them into position 4 Upper Grill Install A Line the rods of...

Страница 21: ...t push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion and loss of warranty 4 Do not use this appliance if an...

Страница 22: ...e top louver then pull out and down to access the gas control valve 2 Set the thermostat to the lowest setting If installed 3 Turn off all electric power to the appliance if service is to be performed...

Страница 23: ...s turned on NOTE If manifold pressure reading is within the normal range an incoming pressure check is not necessary A too high or too low pressure reading warrants an inlet incoming gas pressure chec...

Страница 24: ...eplace the logs glass and upper grill The flow of combustion and ventilation air must not be obstructed IMPORTANT ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING T...

Страница 25: ...t the manual shut off valve 3 Disconnect gas line flex tube from the manual shut off valve 4 Disconnect any wall switch remote control or thermostat wires from the top bottom terminals on the gas valv...

Страница 26: ...assembly and tighten 3 Install the burner tube by positioning it over the burner orifice and aligning the mounting holes at the sides of the burner tube onto the tabs on the millivolt board 4 Position...

Страница 27: ...USE SOLUTION 1 No spark when piezo Piezo wire connection at valve Push wire back into place button is depressed is loose or off Wire from piezo to electrode is Reconnect wire loose at electrode Electr...

Страница 28: ...and tighten screws Generator wire grounded out Nuts securing millivolt board may need due to pinched wires loosening to remove pinched wire Generator is not producing enough Check millivolt reading re...

Страница 29: ...e limit switch 404 4 Limit Switch Assembly 600085 Speed Control REMOTE CONTROLS THERMOSTAT UPPER GRILLS 796 2 Remote Control with thermostat 936 200 Black Upper Grill 797 1 Remote Control 936 20B Bras...

Страница 30: ...urpose This warranty replaces all previous warranty policies This limited warranty will be void if the fireplace is not installed by a qualified installer and according to the installation instruction...

Страница 31: ...o person is authorized to extend the time of this Lifetime warranty or to accept on Hussong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit Hussong Manufac...