LOG INSTALLATION
This log set includes:
(1) W5 Log
(1) W6 Log
(1) W7 Log
(1) Klinker packet
(1) W8 Log
(1) W9 Log
(1) W10 Log
(1) Rock wool ember packet
NOTE:
The logs are numbered on the bottom side - refer to the instructions below for proper placement. The
base logs have mounting holes Incorporated into the bottom of the logs and should be positioned onto
the corresponding mounting studs. Alignment cut-outs have been designed into the logs for positioning.
Their location on the logs are represented as an (*) symbol in the photo below.
FIGURE 10A
Refer to the figure 10A above for steps #1 - #3:
1. Place back base log ‘W5' into position aligning the slots in the bottom of the log (one on each end) onto the
burner cover and the notched out section in the log around the pilot assembly. Once positioned, press down
slightly to secure in place.
2. Position the remaining base logs, ‘W6' & ‘W7' into the center of the burner as shown.
Natural Gas models
:
Push the logs back against the burner tube.
3.
Carefully place the rock wool embers as desired onto the logs and burner tube to create additional glow. Do
not plug burner port holes or use excessively. Place the ‘klinkers’ onto the burner plate and in front of the
burner tube as shown above.
Note: You will not use all the ‘embers’ in the packet - save for future use.
‘Klinkers’
CAUTION: DO NOT COVER THE BURNER PORTHOLES IN FRONT OF THE PILOT.
BLOCKING THESE PORTHOLES MAY RESULT IN DELAYED IGNITION OF THE BURNER.
FIGURE 10B
4. Position the ‘W8’ log, ‘W9' log & ‘W10' log onto the alignment cut-outs as shown in figure 10B.
INITIAL BURN PERIOD
During the initial burn period, the logs and refractory will discolor. This is normal and part of the curing
process. Once the curing process is complete (approximately 2-4 hours), the true color will return.
IMPORTANT: DO NOT BURN THIS FIREPLACE WITHOUT THE GLASS ASSEMBLY IN PLACE.
MAKE SURE THE HOMEOWNER IS AWARE OF THIS!
Page 16