background image

 

9.  Push in the black control knob all the way and hold in. Press the SQUARE igniter button (B). The pilot will 

generally light with two or three pushes on the igniter. Hold the knob in for about one (1) minute after the pilot 
is lit. Release knob and it w ill pop back out. Pilot should remain lit. If it goes out, repeat steps 5 through 9.    

 

*If knob does not pop out when released, stop and 
immediately call your service technician or gas supplier.   
*If the pilot w ill not stay lit after several tries, turn the gas 
control knob to "OFF" and call your service technician or gas 
supplier.  

 
10.  Turn black control knob (A) counterclockwise        to "ON". 
11. Flip the ON/OFF switch (C) to the "ON" position. If using a 

thermostat, leave on/ off switch ‘OFF’ and set the thermostat 
to desired setting. 

12.  Close the lower grill. 
13.  Turn on electric power to the fireplace.  
 

NOTE: When the unit is initially lit, condensation w ill appear on the glass, this is normal in all gas fireplaces, 
and will disappear in one to three minutes. 

 
14. If you wish to turn the burner off, flip the on/ off switch to the ‘OFF’ position. If a w all switch has been 

installed, simply turn it off. I f a thermostat has been installed, simply adjust temperature setting. 

 

NOTE: The pilot w ill stay lit. 

 
TO TURN GAS OFF TO APPLIANCE 
 
1.  Open the lower grill by grasping the center of the top louver, then pull out and down to access the gas 

control valve. 

2.  Set the thermostat to the lowest setting. (If installed) 
3.  Turn off all electric power to the appliance if service is to be performed. 
4.  Push in control knob(A) slightly and turn clockwise ` to “OFF”. Do not force. 

 

KEEP BURNER & CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS ACCOMPANYING APPLIANCE. 

 

 
 
 
 
 
 
 
 
 

 
 
 
 

 

NOTE: Children and adults should be alerted to the hazards of high surface temperature and should stay away 
to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same 
room as the appliance. 
 
Clothing or other flammable material should not be placed on or near the appliance. 
 
 

INITIAL BURN PERIOD 

 

AN ODOR WILL OCCUR DURING THE FIRST FEW HOURS OF BURNING. THIS IS THE PAINT CURING AND SUBSTANCES 

USED IN THE MANUFACTURING PROCESS. IT IS RECOMMENDED TO LEAVE THE FAN (IF INSTALLED) OFF DURING THIS 

PERIOD AS IT WILL SPEED UP THE PAINT CURING PROCESS. 

 
DUE TO THE MAKEUP OF THE LOGS & REFRACTORY, THEY WILL DISCOLOR DURING THE INITIAL BURNER PERIOD. 

THIS MAY TAKE UP TO 4 HOURS OF BURN TIME. ONCE THE CURING PROCESS IS COMPLETE, THE TRUE COLOR WILL 

RETURN. 

 

IMPORTANT:

 DO NOT BURN THIS FIREPLACE WITHOUT THE GLASS ENCLOSURE PROPERLY IN PLACE. 

**MAKE SURE THE HOMEOWNER IS AWARE OF THIS**

NOTE:  THIS FIREPLACE MAY PRODUCE NOISES OF VARYING DEGREE AS IT HEATS AND COOLS TO DUE METAL 

EXPANSION AND CONTRACTION. THIS IS NORMAL AND DOES NOT AFFECT THE PERFORMANCE OR 

LONGEVITY OF THE FIREPLACE.

 

Page 20

Содержание windom 56101

Страница 1: ...must be performed by a qualified installer service agency or the gas supplier MODEL 56101 WINDOM DIRECT VENT GAS FIREPLACE INSTALLATION AND OPERATING MANUAL This appliance may be installed in an afte...

Страница 2: ...ed heating appliance or equipment The sign shall read in print size no less than inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state of local gas inspector of the...

Страница 3: ...S 10 REMOVE THE GLASS ASSEMBLY 11 DIRECT VENT CHIMNEY INSTALLATION 11 FAN INSTALLATION 12 13 GAS LINE SPECIFICATIONS 14 15 SECURE THE MILLIVOLT BOARD 15 LOG INSTALLATION 16 THERMOSTAT WALL SWITCH REMO...

Страница 4: ...Current Edition SPECIFICATIONS Height front 32 Height back 30 1 8 Front width 36 Back width 23 3 8 Depth 11 Flue size 4 exhaust 6 5 8 combustion air intake PASS THRU WALL THICKNESS The Dura Vent DV G...

Страница 5: ...ance and to replace any part of the control system and any gas control which has been under water CONSULT YOUR LOCAL OR NATIONAL INSTALLATION CODES TO ASSURE THAT ADEQUATE COMBUSTION AND VENTILATION A...

Страница 6: ...IPE TO FINISHED WALL REQUIRED 1 Clearance at sides 1 Clearance at sides 2 1 4 1 54 3 4 38 5 8 KOZY HEAT CORNER CABINET INSTALLATION MODEL 56101 WINDOM CORNER CABINET DIMENSIONS FIGURE 2C MODEL 56101 W...

Страница 7: ...MPORTANT Consult the local and national installation codes to assure that adequate combustion and ventilation air is available MINIMUM MAXIMUM VENTING REQUIREMENTS Minimum vertical rise maximum horizo...

Страница 8: ...ide inside corner 12 F 7 Meter Regulator not to be installed above within 3 ft horizontally from the center line of the regulator 8 Service regulator vent outlet 3 ft radius 9 Electrical box 3 ft G DO...

Страница 9: ...tion cap Maximum horizontal run 14 ft 1 4 incline for each horizontal foot of chimney must be maintained WALL THIMBLE 6 22 3 8 TO CENTER OF VENT PIPE 26 TO TOP OF VENT PIPE 1 CLEARANCE AT THE TOP FOR...

Страница 10: ...rmation WHEN VERTICALLY TERMINATING THE MINIMUM CHIMNEY HEIGHT ABOVE THE ROOF LINE IS DETERMINED BY THE FOLLOWING CHART Roof Pitch Minimum Chimney Height Roof Pitch Minimum Chimney Height Flat to 6 12...

Страница 11: ...in compliance with the guidelines on page 6 of this manual 2 Determine the width depth and height of the optional hearth NOTE A hearth is not required If a hearth is desired combustible materials may...

Страница 12: ...ir around the unit Air enters the unit at the lower grill and exits at the upper grill Blocking these passages may result in overheating the fireplace creating a potentially hazardous situation 6 Plac...

Страница 13: ...age from the firebox and set aside HORIZONTAL VERTICAL VENTING APPLICATIONS 1 INSTALL THE CHIMNEY SYSTEM FOR YOUR VENTING CONFIGURATION FOLLOWING THE CHIMNEY MANUFACTURERS INSTRUCTIONS INCLUDED WITH T...

Страница 14: ...includes 1 Right and left fan assemblies with fans with temperature control switch 2 Components Package Speed control with mounting bracket nut knob installation instructions NOTE To wall mount the s...

Страница 15: ...wiring with ground through the romex connector installed in the electrical box and wire to the receptacle 6 Secure receptacle into the electrical box 7 Install the cover onto the electrical box and s...

Страница 16: ...ffixed to the flexible tubing for additional installation instructions and warnings NOTE For high altitude installations consult the local gas distributor or the authority having jurisdiction for prop...

Страница 17: ...rom the gas supply piping system during any pressure testing of that system at test pressures in excess of psi NOTE The appliance must be isolated from the gas supply piping system by closing its indi...

Страница 18: ...remaining base logs W6 W7 into the center of the burner as shown Natural Gas models Push the logs back against the burner tube 3 Carefully place the rock wool embers as desired onto the logs and burne...

Страница 19: ...es from the top bottom terminals on the gas valve Follow instructions included with the remote control Remote Control Wiring Diagram CAUTION DO NOT CONNECT HIGH VOLTAGE 115V WIRE TO THE GAS VALVE REMO...

Страница 20: ...embly to the fireplace by pulling the two spring loaded handles located under the firebox out and up over the latch brackets Release locking them into position 4 Upper Grill Install A Line the rods of...

Страница 21: ...t push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion and loss of warranty 4 Do not use this appliance if an...

Страница 22: ...e top louver then pull out and down to access the gas control valve 2 Set the thermostat to the lowest setting If installed 3 Turn off all electric power to the appliance if service is to be performed...

Страница 23: ...s turned on NOTE If manifold pressure reading is within the normal range an incoming pressure check is not necessary A too high or too low pressure reading warrants an inlet incoming gas pressure chec...

Страница 24: ...eplace the logs glass and upper grill The flow of combustion and ventilation air must not be obstructed IMPORTANT ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING T...

Страница 25: ...t the manual shut off valve 3 Disconnect gas line flex tube from the manual shut off valve 4 Disconnect any wall switch remote control or thermostat wires from the top bottom terminals on the gas valv...

Страница 26: ...assembly and tighten 3 Install the burner tube by positioning it over the burner orifice and aligning the mounting holes at the sides of the burner tube onto the tabs on the millivolt board 4 Position...

Страница 27: ...USE SOLUTION 1 No spark when piezo Piezo wire connection at valve Push wire back into place button is depressed is loose or off Wire from piezo to electrode is Reconnect wire loose at electrode Electr...

Страница 28: ...and tighten screws Generator wire grounded out Nuts securing millivolt board may need due to pinched wires loosening to remove pinched wire Generator is not producing enough Check millivolt reading re...

Страница 29: ...e limit switch 404 4 Limit Switch Assembly 600085 Speed Control REMOTE CONTROLS THERMOSTAT UPPER GRILLS 796 2 Remote Control with thermostat 936 200 Black Upper Grill 797 1 Remote Control 936 20B Bras...

Страница 30: ...urpose This warranty replaces all previous warranty policies This limited warranty will be void if the fireplace is not installed by a qualified installer and according to the installation instruction...

Страница 31: ...o person is authorized to extend the time of this Lifetime warranty or to accept on Hussong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit Hussong Manufac...

Отзывы: